beautypg.com

Technical specifications – IMP Pumps NMT(D) SMART (C) User Manual

Page 21

background image

-21-

GB

NMTD SMART C

In this mode both pumps can work in different modes, switching between

pumps is made by NMTC module.

- Alternating mode [factory set] - One pump works, while the other one is

in standby. Pumps automatically switch on and in to standby every 24

hours, or when an error occurs on one pump.

- Reserve mode - One pump is always on, while the other one is in standby.

If an error occurs, then the reserve pump will turn on. This mode is turned

on, so that you put the pump that you want to be in standby, to standby by

holding

key for 5 seconds.

- Combined mode – both pumps work with the same head in constant

pressure mode. This mode is used when there is a need for a flow that a

single pump can't reach. When the limit of the first pump is reached, then

the other one will turn on supply the needed power to reach that flow.

This mode is activated, so that you set the same constant pressure head

on both pumps.

NMTD SMART

In this mode the pumps can work in different modes. The user takes care of

switching on and off of the pumps.

- Reserve mode - One pump works, while the other one is in standby. It is

recommended that the reserve pump is turned on at least once a month.

- Combined mode – Both pumps work, regardless of each other. Pumps

need to be set at the same constant speed.

6.

Technical specifications

NMT(D) SMART (C)

Pump type

xx/120-xxx

xx/100-xxx

xx/80-xxx

xx/60-xxx

xx/40-xxx

Power P

1

10-180W

10-180W

10-140W

10-90W

10-60W

Rated current In

0,1-1,55A

0,1-1,5A

0,1-1,15A

0,1-0,75A

0,1-0,5A

Power supply

1~230V, 50Hz

Motor protection

External protection is not necessary

Protection class

IP44

Insulation class

F

Relative humidity

max 95%

Ambient temperature

0-40°C

Medium temperature

2-110°C

System pressure

up to 1 MPa (10 bar)