TALK GROUP IDS
You can program up to 100 talk group
IDs in each bank. When the scanner
stops on a transmission in the LTR,
Motorola, or EDACS mode, it checks
to see if the ID has been stored. In the
closed mode, the scanner only stops
on the transmission and displays its
text tag if you have stored and not
locked out the ID. In the open mode,
the scanner always stops on a trans-
mission, but it displays the ID’s text
tag if you have stored the ID.
Storing Talk Group IDs
To store a talk group ID when scan-
ning, press
TRUNK
when the scanner
stops on a transmission. The bottom
line changes to
ID#XXXX
indicating
that the ID is stored.
Note: When you try to store more than
100 talk group IDs in a bank,
Memory
full!
appears. Clear some talk
group IDs in order to store new ones
(see “Clearing a Talk Group ID” on
Page 42).
Follow these steps to manually store
talk group IDs or to edit a stored ID.
1. Press
PROG
.
2. Press
TRUNK
.
3. To select the bank you want to
store the ID to, repeatedly press
FUNC
and
▲
or
▼
.
4. Repeatedly press
MODE
to select
LT
,
MO
, or
ED
.
5. Enter the talk group ID and press
ENTER
. If necessary, use the deci-
mal point for a hyphen.
Note: If you made a mistake in
Step 5,
Invalid ID.
appears
and the scanner beeps when you
press
ENTER
. Start again at Step
5.
6. Press
TEXT
and enter the text tag
for the ID and press
ENTER
.
7. To store the next ID memory in
sequence, press
▲
and repeat
Steps 4 and 5 or 6 to enter more
IDs.
8. Press
SCAN
to start scanning.
Talk Group ID Hold
You can set your scanner to follow a
trunking signal that you want to track
during scanning. Hold down
TRUNK
for more than 2 seconds. You see:
To release
ID
hold
ON.
, press
SCAN
or
TRUNK.
Locking Out Talk Groups ID
Note: You can only lock out talk group
IDs when the scanner is in the closed
mode (see “Open and Closed Modes”
on Page 43).