beautypg.com

Mode 1 input timing, Figure 3-5. mode 1 timing specification for input, Mode 1 input timing -12 – National Instruments PC-DIO-24/PnP User Manual

Page 35: Figure 3-5

background image

Chapter 3

Signal Connections

PC-DIO-24/PnP User Manual

3-12

© National Instruments Corporation

Mode 1 Input Timing

The following figure illustrates the timing specifications for an input
transfer in mode 1.

Figure 3-5. Mode 1 Timing Specification for Input Transfers

Name

Description

Minimum

Maximum

T1

STB* pulse width

100

T2

STB* = 0 to IBF* = 1

150

T3

Data before STB* = 1

20

T4

STB* = 1 to INTR = 1

150

T5

Data after STB* = 1

50

T6

RD* = 0 to INTR = 0

200

T7

RD* = 1 to IBF = 0

150

All timing values are in nanoseconds.

T3

T5

T6

T7

T4

T1

T2

STB*

IBF

INTR

RD*

DATA