beautypg.com

Nortel Networks Remote Gateway 50 User Manual

Page 233

background image

Emergency Services configuration

Page 233 of 258

Main Office Configuration for Survivable Remote Gateway 50

Configuration Guide

a.

Configure the branch office zone’s ESA dialing information in
LD 117.

b.

Enable the

branch

office zone ESA in LD 117.

ENL ZBR ESA

7

Configure the ESA Special Number at the main office.

a.

Configure the ESA Special Number in the NRS. Using NRS,
configure the ESA Special Number defined for the

branch

office

zone. Refer to IP Peer Networking: Installation and Configuration
(553-3001-213).

Nortel recommends that customers use “0” + the ESN Location code
+ ESDN. An example for location code 725 would be 0725911. The
zero is recommended to prevent a collision in the ESN data with the
HLOC entry.

LD 117 – Configure branch office zone ESA route.

Command

Description

CHG ZESA

Defines the ESA parameters for the

branch

office zone, where:

Zone = Zone number for the

branch

office.

ESA Route # = Virtual Trunk route to SRG.

AC = Access Code to add to dialed digits. If no AC is required, enter
AC0 in place of AC1 or AC2.

ESA Prefix = Digit string added to start of ESDN. This is a unique prefix
in the NRS. Nortel recommends that users use “0” + ESN location code
of the

branch

office node. An example for location code 725 would be:

0725.

ESA Locator = Direct Inward Dial telephone number sent as part of ANI
for use by the PSAP to locate the source of the call.