Time code, Setup menus – Panasonic AJ-HD1700PE User Manual
Page 91
91
Setup menus
The underlining (__) denotes the factory setting mode.
No./Item
Description of setting
500*
4
VITC BLANK
For selecting whether or not to output the
VITC signal at the positions selected by setup
menu items No.501 (VITC POS-1) and No.502
(VITC POS-2).
0000
BLANK:
The VITC signal is not output.
0001
THRU:
The VITC signal is output.
501*
4
VITC POS-1
For setting the position where the VITC signal
is to be inserted.
<59/60Hz>
<50Hz, 25Hz (SD)>
0000
10L
0000
7L
:
:
:
:
0006
16L
0004
11L
:
:
:
:
0010
20L
0015
22L
item No.502 (VITC POS-2) cannot be selected.
• Only the SD output takes effect at this setting.
505*
1
TCG REGEN
For selecting the regeneration signal when
REGEN has been selected as the TCG (time
code generator) mode.
0000
TC&UB:
Regeneration applies to both the time code
and user’s bit.
0001
TC:
Regeneration applies only to the time code only.
0002
UB:
Regeneration applies only to the user’s bit only.
506*
1
REGEN MODE
For selecting the editing mode range when
the VTR is operating in the REGEN mode
while performing editing operations with
“AUTO” selected as the setup menu item
No.503 (TCG MODE) setting.
0000
AS&IN:
Regeneration applies during assemble or
insert editing.
0001 ASSEM:
Regeneration applies during assemble editing.
0002
INSRT:
Regeneration applies during insert editing.
507*
1
TC SOURCE
For selecting the time code to be used when
HD SDI or SD SDI has been selected as the
setup menu item No.600 (VIDEO IN SEL)
setting when an external time code is to be
used.
[When HD SDI has been selected]
0000
INT:
The time code of the internal time code
generator is used.
0001
EXT_L:
LTC of the TIME CODE IN connector is used.
0002
SLTC:
The LTC information added to the serial
signals which are input to HD SDI IN is used.
0003
SVITC:
The VITC information added to the serial
signals which are input to HD SDI IN is used.
[When SD SDI has been selected]
0000
INT:
The time code of the internal time code
generator is used.
0001
EXT_L:
LTC of the TIME CODE IN connector is used.
0002
VITC:
The VITC information added to the serial
signals which are input to SD SDI IN is used.
code is converted as shown below.
[HD_SDI]
[SD_SDI]
INT
↔
INT
EXT_L
↔
EXT_L
SLTC
↔
EXT_L
SVITC
↔
VITC
502*
4
VITC POS-2
For setting the position where the VITC signal
is to be inserted.
<59/60Hz>
<50Hz, 25Hz (SD)>
0000
10L
0000
7L
:
:
:
:
0008
18L
0006
13L
:
:
:
:
0010
20L
0015
22L
item No.501 (VITC POS-1) cannot be selected.
• Only the SD output takes effect at this setting.
503*
1
TCG MODE
For setting the synchronization of the internal
time code generator.
0000 REGEN:
The time code reader is synchronized with the
time code which is read from the tape.
0001
PRE:
Presetting is enabled at the operation panel or
by the remote controller.
0002
AUTO:
The
REGEN
and
PRE
settings
are
automatically switched in accordance with the
operation mode.
In the editing mode: REGEN is selected.
In all other modes:
PRE is selected.
504*
1
RUN MODE
For setting when the internal time code
generator is to advance depending on the
operation mode.
0000
REC:
The time code generator is advanced during
recording.
0001
FREE:
The time code generator is advanced while the
power is on regardless of which operation
mode is established.
No./Item
Description of setting
*1: This item is not displayed when the 23/24 Hz or 25 Hz (HD or SD) mode
has been selected as the system menu item No.25 (SYSTEM FREQ)
setting.
*2: This item is not displayed when the 23/24 Hz or 25 Hz (HD) mode has
been selected as the system menu item No.25 (SYSTEM FREQ) setting.