Lucent Technologies Host-Based Controller Modem AT User Manual
Page 67
Data Addendum
Host-Based Controller Modem
June 15, 1998
AT Command Set
AT Commands for Homologation Testing and Debugging (continued)
Version 1.0
Lucent Technologies Inc.
67
Table 13. The Homologation Parameters (continued)
Par #
Parameter Description
Range
Reference
31
TAD receive gain
0—255
—
32
Half/full wave ring detection
0 = halfwave, 1 = fullwave
—
33
Number of failed attempts allowed in first stage
delayed dialing
0—255
ATD
34
Number of all failed attempts ( to any number)
allowed before any further dial attempts are blocked
0—255
255 = not applicable
ATD
35
Erroneous call increment count
0—255
ATD
36
Dial tone validation time in multiples of 100 ms
0—255
ATD
37
Busy tone detection during dial tone detection flag
0 = not required, 1 = required
ATD
38
DTMF high and low tone level difference in dB
0—255
—
39
Local phone detection in speakerphone
0 = enabled; 1 = disabled
—
3a
Pulse dialing flag
0 = enabled; 1 = disabled
ATD
3b
Dial tone/call progress filter index
0 = 340—560 Hz 1 = 310—485 Hz
2 = 363—502 Hz 3 = 276—504 Hz
4 = 415—460 Hz 5 = 310—640 Hz
—
3c
Dial tone detection threshold in dB
0—255
—
3d
ABCD dialing permitted flag
0 = permitted, 1 = not permitted
ATD
3e
Comma pause duration limit in seconds. (If there are
multiple commas between digits, the total pause
duration is limited to the duration set by this
parameter).
0—255
ATD
3f
TAD transmit level in dB
0—255
—
40
Data/FAX carrier receive threshold in dB. There is a 6
dB offset in DSP. This parameter value should set to:
(required threshold [6 dB] DAA gain)
0—255
—
41
No dialtone time-out duration while detecting dialtone
with W dial modifier, in seconds
0—255
ATD
42
FAX/Data answer tone detection threshold in dB
0—255
—
43
Dialtone level (absolute value)
0—255
—
44
FAX receive threshold in dB
0—255
—
45
Pulse and tone dial in same dial string permitted flag
0 = permitted, 1 = not permitted
ATD
46
Ringer impedance relay flag
0 = off, 1 = on
47
DC loop V/I characteristics relay flag
0 = off, 1 = on
48
DC loop limiting relay flag
0 = off, 1 = on
49
Real/complex impedance
0x0X = real, Tx & Rx gains set by mercury
internal components. X = Don’t care
0x10 = real, Tx gain set by mercury
internal components & Rx gain set by
external components.
0x12 = complex, Tx gain set by mercury
internal components & Rx gain set by
external components. Mercury internal
switch used to select complex impedance.
4a
Mercury register CIOCA MSB value—receive gain
This parameter is relevant only when a Mercury
line codec is used.
—