beautypg.com

Lucent Technologies Host-Based Controller Modem AT User Manual

Page 66

background image

Host-Based Controller Modem

Data Addendum

AT Command Set

June 15, 1998

AT Commands for Homologation Testing and Debugging (continued)

Lucent Technologies Inc.

Version 1.0

66

Table 13. The Homologation Parameters (continued)

Par #

Parameter Description

Range

Reference

19

Number of failed attempts allowed before
blacklisting

0—255

ATD

1a

Troubled call delay in minutes

0—255

ATD

1b

Ineffective call delay in minutes

0—255

ATD

1c

Erroneous call delay in minutes

0—255

ATD

1d

Blacklisting duration in multiple of 10 minutes

0—255;
0 = only delayed and no blacklisting
255 = no limit (i.e., till power turned off)

ATD

1e

Over-current sense validation time in
multiples of 10 ms

0—255, 0 = current sense disabled.

ATA, ATD

1f

Calling tone flag

0 = disabled
1 = enabled, and disable with ^ dial
modifier permitted
2 = enabled, and disable with ^ dial
modifier not permitted

ATD , S35

20

Blind dial flag

0 = not permitted
1 = permitted
2 = permitted with speaker on

ATD , ATX

21

Busy detect disable (with ATX) flag

0 = not permitted
1 = permitted

ATD , ATX

22

Guard tone type

0 = not present & adjustable
1 = 550 Hz, 2 = 1800 Hz

S37

23

Bell modes permitted flag

0 = not permitted
1 = permitted

ATB

24

Off-hook (ATH1) restrictions

0 = no restrictions
1 = restricted by S7 duration
2 = not allowed

ATH1

25

Shunt relay on time during off-hook in
multiples of 10 ms.

0—255
0 = shunt relay disabled

ATD

26

Hook flash time in multiples of 10 ms

0—255
0 = hook flash not allowed

ATD

27

Min. blind dial pause in seconds

0—65

S6

28

Max. blind dial pause in seconds

0—65

S6

29

Min. no answer time-out in seconds

0—65

S7

2a

Max. no answer time-out in seconds

0—65

S7

2b

Min. dial pause time in seconds

0—65

S8

2c

Max. dial pause time in seconds

0—65

S8

2d

Min. no carrier disconnect time in multiples of
100 ms

1—65

S10

2e

Max. no carrier disconnect time in multiples of
100 ms

1—255

S10

2f

Transmit level in dB with implied minus sign

0—255

ATD

30

Dial modifier validation

0 = if an invalid dial modifier is found, treat the

entire dial string as null (no digits dialed)

1 = ignore invalid dial modifiers