beautypg.com

Lucent Technologies Host-Based Controller Modem AT User Manual

Page 65

background image

Data Addendum

Host-Based Controller Modem

June 15, 1998

AT Command Set

AT Commands for Homologation Testing and Debugging (continued)

Version 1.0

Lucent Technologies Inc.

65

Homologation Parameters

Table 13. The Homologation Parameters

Par #

Parameter Description

Range

Reference

1

Pulse dial make time

0—255

ATD

2

Pulse dial break time

0—255

ATD

3

Pulse dial digit pattern

1 = normal, 2 = Sweden,
3 = Norway

ATD

4

DTMF high tone level in dB with implied minus sign

0—255

ATD

5

Min. DTMF dial speed in ms

0—255

S11

6

Max. DTMF dial speed in ms

0—255

S11

7

Call progress detection threshold in dB with implied minus
sign

0—255

8

Dial tone delay, i.e., waiting time before dial tone
detection begins in multiples of 10 ms

0—255

9

Dial tone hole time in ms

0—255

a

Delay before resetting ring count to 0, in multiples of 100
ms

0—255

b

Min. ring count for auto-answer

0—255

S0

c

Max. ring count for auto-answer

0—255

S0

d

Min. ring signal period =
1000/(0.833 x Max. ring frequency)

0—255

e

Max. ring signal period =
1000/(0.833 x Min. ring frequency)

0—255

f

Min. ring cadence on time, in multiples of 10 ms

0—255

10

Min ring cadence off time, in multiple of 20 ms

0—255

11

Min. busy cadence on time, in multiples of 10 ms

0—255; If 0, use the standard
busy detection algorithm;
otherwise, use the country
specific values for cadence

12

Max. busy cadence on time, in multiples of 10 ms

0—255; If 0, use the standard
busy detection algorithm;
otherwise, use the country
specific values for cadence

13

Number of busy cycles required to detect busy condition

0—255

14

Min. busy cadence off time, in multiples of 10 ms

0—255; If 0, use the standard
busy detection algorithm;
otherwise, use the country
specific values for cadence

15

Max. busy cadence off time, in multiples of 10 ms

0—255; If 0, use the standard
busy detection algorithm;
otherwise, use the country
specific values for cadence

16

Continuous # unavailable detection flag

0 = disabled, 1 = enabled

17

Answer tone validation time in multiples of 10 ms

0—255

18

Blacklisting/delayed flag

0 = disabled, 1 = enabled

ATD