IBM xSeries 330 User Manual
Page 96
88
Hardware Maintenance Manual: xSeries 330
035-253-S99
(RAID adapter
initialization failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain
the basic and extended configuration status and refer to the
ServeRAID Hardware Maintenance Manual for more information.
2.
Cable
3.
SCSI Backplane
4.
Adapter
089-XXX-001
(Failed Microprocessor
test)
1.
Microprocessor 1
2.
System Board
089-XXX-002
(Failed
Optional Microprocessor test)
1.
Microprocessor 2
2.
System Board
165-XXX-000
(Failed Service Processor
test)
1.
System Board
180-XXX-000
(Diagnostics LED failure)
1.
Run Diagnostic LED test for the failing LED.
180-XXX-001
(Failed information LED
panel test)
1.
Switch Card / Information LED Panel
180-XXX-003
(Failed System Board LED
test)
1.
System Board
180-XXX-005
(Failed SCSI
Backplane LED test)
1.
SCSI Backplane
2.
SCSI Backplane Cable
3.
System Board
201-XXX-0NN
(Failed Memory test,
see "Memory Settings" on page 33)
1.
DIMM Location slots 1-4 where NN = DIMM location.
Note:
NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN
4=DIMM 4
2.
System Board
201-XXX-999
(Multiple DIMM failure, see
error text)
1.
See error text for failing DIMMs
2.
System Board
202-XXX-001
(Failed System Cache
test)
1.
Microprocessor 1
2.
System Board
202-XXX-002
(Failed System Cache test) 1.
Microprocessor 2
2.
System Board
206-XXX-000
(Failed Diskette Drive
test)
1.
Try test with another diskette
2.
Cable
3.
Diskette Drive
4.
System Board
215-XXX-000
(Failed IDE CD-ROM
test)
1.
CD-ROM Drive Cables
2.
CD-ROM Drive
3.
System Board
217-XXX-000
(Failed Fixed Disk
test)
Note:
If RAID is configured, the fixed
disk number refers to the RAID
logical array
1.
Fixed Disk 1
2.
System Board
Error Code/Symptom