beautypg.com

IBM xSeries 330 User Manual

Page 96

background image

88

Hardware Maintenance Manual: xSeries 330

035-253-S99

(RAID adapter

initialization failure)

1.

ServeRAID Adapter in slot S is not configured properly.

Obtain

the basic and extended configuration status and refer to the
ServeRAID Hardware Maintenance Manual for more information.

2.

Cable

3.

SCSI Backplane

4.

Adapter

089-XXX-001

(Failed Microprocessor

test)

1.

Microprocessor 1

2.

System Board

089-XXX-002

(Failed

Optional Microprocessor test)

1.

Microprocessor 2

2.

System Board

165-XXX-000

(Failed Service Processor

test)

1.

System Board

180-XXX-000

(Diagnostics LED failure)

1.

Run Diagnostic LED test for the failing LED.

180-XXX-001

(Failed information LED

panel test)

1.

Switch Card / Information LED Panel

180-XXX-003

(Failed System Board LED

test)

1.

System Board

180-XXX-005

(Failed SCSI

Backplane LED test)

1.

SCSI Backplane

2.

SCSI Backplane Cable

3.

System Board

201-XXX-0NN

(Failed Memory test,

see "Memory Settings" on page 33)

1.

DIMM Location slots 1-4 where NN = DIMM location.

Note:

NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN
4=DIMM 4

2.

System Board

201-XXX-999

(Multiple DIMM failure, see

error text)

1.

See error text for failing DIMMs

2.

System Board

202-XXX-001

(Failed System Cache

test)

1.

Microprocessor 1

2.

System Board

202-XXX-002

(Failed System Cache test) 1.

Microprocessor 2

2.

System Board

206-XXX-000

(Failed Diskette Drive

test)

1.

Try test with another diskette

2.

Cable

3.

Diskette Drive

4.

System Board

215-XXX-000

(Failed IDE CD-ROM

test)

1.

CD-ROM Drive Cables

2.

CD-ROM Drive

3.

System Board

217-XXX-000

(Failed Fixed Disk

test)

Note:

If RAID is configured, the fixed
disk number refers to the RAID
logical array

1.

Fixed Disk 1

2.

System Board

Error Code/Symptom

FRU/Action