Chapter 7. Symptom-to-FRU index

93

0001200

(Machine check architecture

error)

1.

Processor 1

2.

Optional Processor 2

3.

System Board.

1600

(The Service Processor is not

functioning) Do the following before
replacing a FRU:

1.

Do the following before replacing a FRU:

a.

Ensure that a jumper is not installed on J28.

b.

Remove the ac power to the system, wait 20 seconds; then, re-
connect the ac power. Wait 30 seconds; then, power-on the
system.

2.

System Board

1601

(The system is able to

communicate to the Service Processor, but
the Service Processor failed to respond at
the start of POST.)

1.

Do the following before replacing a FRU:

a.

Remove the ac power to the system, wait 20 seconds; then, re-
connect the ac power. Wait 30 seconds; then, power-on the
system.

b.

Flash update the Service Processor.

2.

System Board

1762

(Fixed Disk Configuration error)

(IDE drive only)

1.

Fixed Disk Drive

2.

Fixed Disk Cables

3.

Run Configuration/Setup

4.

System Board

178X

(Fixed Disk error) (IDE drive

only)

1.

Fixed Disk Cables

2.

Run Diagnostics

3.

Fixed Disk Drive

4.

System Board

1800

(No more hardware interrupt

available for PCI adapter)

1.

Run Configuration/Setup

2.

Remove Adapter

1801

(no more ROM space available for

PCI adapter)

1.

Run Configuration/Setup

2.

Remove adapter

3.

Disable adapter BIOS on adapter and run Configuration/Setup

1962

(Drive does not contain a valid

boot sector)

1.

Verify a bootable operating system is installed.

2.

Run Diagnostics

3.

Hard Disk Drive

4.

SCSI Backplane

5.

Cable

6.

System Board

2400

(Video controller test failure)

1.

Video Adapter (if installed)

2.

System Board

2462

(Video memory configuration

error)

1.

Video Adapter (if installed)

2.

System Board

Error Code/Symptom