Intel Server Board S5000PAL User Manual
Page 93

Appendix B: Sensor Tables
Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision
1.4
Intel order number: D31979-007
94
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Criticality
Assert /
De-assert
Readable
Value /
Offsets
Event Data
Rearm
Standby
Sensor 
Failure 
86h All Sensor
Failure 
F6h 
OEM 
Sensor 
Specific 
73h 
I
2
C device not
found 
I
2
C device error
detected 
I
2
C bus timeout
OK As
–
Trig
Offset
A X
NMI Signal 
State 
87h All OEM
C0h
Digital 
Discrete 
03h 
01h – State 
asserted 
OK –
01h
–
–
–
SMI Signal 
State 
88h All OEM
C0h
Digital 
Discrete 
03h 
01h – State 
asserted 
OK –
01h
–
–
–
IERR Critical 
Thermal trip 
Non-rec
Config error
Critical
Presence OK
Proc 1 
Status 
90h All Processor
07h
Sensor 
Specific 
6Fh 
Disabled Degraded
As and De
–
Trig Offset
M
X
IERR Critical 
Thermal trip 
Non-rec
Config error
Critical
Presence OK
Proc 2 
Status 
91h All Processor
07h
Sensor 
Specific 
6Fh 
Disabled Degraded
As and De
–
Trig Offset
M
X
Proc 1 
Temp 
98h All Temperature
01h
Threshold 
01h 
[u,l] [c,nc]
Threshold 
defined 
As and De Analog
R, T
A
–
Proc 2 
Temp 
9Ah All Temperature
01h
Threshold 
01h 
[u,l] [c,nc]
Threshold 
defined 
As and De Analog
R, T
A
–
Bus correctable 
error 
OK
PCIe Link0 A0h
Critical 
Interrupt 
13F 
Sensor 
Specific 
6Fh 
PCIe 
Link0 
Bus 
uncorrectable 
error 
Degraded
As –
See
the
BIOS EPS
A –