beautypg.com

External control – Marantz PD4292D User Manual

Page 55

background image

49

External Control

plasma monitor

External equipment
e.g., Personal computer

1) Connector on the plasma monitor side: EXTERNAL

CONTROL connector.

Type of connector: D-Sub 9-pin male

No.

Pin Name

1

No Connection

2

RXD (Receive data)

3

TXD (Transmit data)

4

DTR (DTE side ready)

5

GND

6

DSR (DCE side ready)

7

RTS (Ready to send)

8

CTS (Clear to send)

9

No Connection

Application

These specifications cover the communications control of
the plasma monitor by external equipment.

Connections

Connections are made as described below.

2) Connector on the external equipment side: Serial port

(RS-232C) connector
See the specifications of the equipment that is to be
connected for the type of connector and the pin
assignment.

3) Wiring

Use a crossed (reverse) cable.

Wire the cable so that each pair of data lines cross
between the two devices. These data line pairs are RXD
(Receive data) and TXD (Transmit data), DTR (DTE
side ready) and DSR (DCE side ready), and RTS (Ready
to send) and CTS (Clear to send).

Communication Parameters

(1) Communication system

Asynchronous

(2) Interface

RS-232C

(3) Baud rate

9600 bps

(4) Data length

8 bits

(5) Parity

Odd

(6) Stop bit

1 bit

(7) Communication code

Hex

1

5

9

6

PD4292D-2

00.10.4, 3:11 PM

49