GKS9 WIRING DIAGRAM
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
H
IG
H
V
O
LTA
G
E
!
D
IS
CO
NNE
CT
AL
L
PO
WER
BE
F
O
RE
SE
R
V
IC
IN
G
OR
IN
S
T
A
LLI
N
G
TH
IS
UNI
T
.
M
U
LTI
P
L
E
PO
WER
S
O
U
RCE
S
MA
Y
BE
PR
E
S
EN
T
. F
AIL
U
RE
TO
DO
SO
MA
Y
CAU
S
E
PR
O
P
E
R
T
Y
DAM
AG
E
,
P
E
RS
O
NAL
INJ
URY
OR
DE
AT
H
.
R
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BL BLUE
GY
GRAY
RD RED
COLOR CODES:
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
H
I VOLTAGE FIELD
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2
. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
0140F00236 REV. C
O
R (MED LOW)
BL (MED)
RD (LOW )
GAS VALVE
C2
C
G
W
INTERNAL TO
INTEGRATED CONTROL
JUNCTION
E
QUIPMENT GND
FIELD GND
DIAGNOSTIC
L
ED
2
CIRCUIT
CONNECTOR
H
OT
SURFACE
IGNITER
OVERCURRENT
PROT. DEVICE
I
GNITER
T
H (3)
INTEGRATED
CONTROL MODULE
JUNCTION BOX
L
INE-H
XFMR-H
IN
TE
GRA
T
ED
CO
NTRO
L
MO
DUL
E
IN
TE
GRA
T
ED
CO
NTR
O
L
MOD
U
L
E
G
ND
D
ISCONNECT
L
N
OVERCURRENT PROTECTION DEVICE
RD
BL
BK
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED
BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105
TERMINAL
S
WITCH (PRESS.)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
P
K PINK
1
15 VAC HOT AND PARK TERMINALS
LINE-H
F
LAME
SE
NSOR
BK
PLUG CONNECTION
FIELD SPLICE
S
WITCH (TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
G
R
G
ND
115 VAC
24 VAC
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
DOOR
SWITCH
BK
GND
L
N
WH
JUNCTION
BOX
1
O
R
ID BLOWER
PRESSURE
SWITCH
H
EAT-H
GND
W H
RD
WH
GND
BURNER COMPARTMENT
BLOWER COMPARTMENT
NOTE 4
SEE
N
O
C
OOL-H
BK (HI)
BR
B
R
CAPACITOR
Y
L
WH
B
L
PU
RD
OR
PK
BK
WH
WH
BL
OWER
INDUCED DRAFT
MANUAL RESET
A
UXILIARY LIMIT
IN UPFLOW
BLOWER DECK
C
FS
HE
AT
-H
CO
OL
I
GNITER
HOT SURFACE
IND
IGN
BLWR
CIRCULATOR
BLWR
I
D
FLAME SENSOR
115 VAC
T
RANSFORMER
4
0 VA
24 VAC
GND
RO1 (5)
RO2 (11)
HLO (1)
HLI (7)
MVC (9)
GND (8)
TR (6)
OR
WH
WH
BL
YL
OR
RD
GR
BR
PK
PK
W
H
11
5
V
A
C NE
U
T
RA
L
BK
BK
BK
G
Y
2
4
V
T
H
ER
M
O
ST
A
T
C
O
NNEC
T
IO
NS
MICRO
TO
C
G
Y
W
R
2
WH
OR
BL
YL
OR
PK
RD
OR
WH
XF
M
R
-H
TE
R
M
IN
A
L
S
BL
GY
GR
1
2
3
12
11
1
0
9
8
7
6
5
4
°C. USE COPPER CONDUCTORS ONLY.
2
4 VAC
H
UMIDIFIER
24 VAC
HUMIDIFIER
H
UMIDIFIER
P
SO (4)
MV(12)
PS (10)
C
NO
ID BLOWER
PRESSURE
SWITCH
0
C
6
5
4
3
2
1
OFF = CONTROL FAILURE
STEADY ON = NORMAL OPERATION
1 FLASH =
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
3 FLASHES = PRESSURE SWITCH STUCK OPEN
4 FLASHES = OPEN HIGH LIMIT
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
6 FLASHES =
CONTINUOUS/RAPID FLASHES = REVERSED 115 VA C POLARITY
CONTROL
MODULE
I
NTEGRATED
FUSE
MI
G
Y
GY
M1
GAS
VALVE
C2
TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
PU
Y
BR
GY
BR
L
INE NE
UT
RA
L
S
NO
C
O
PTIONAL FRONT COVER
PRESSURE SWITCH
C
N
O
OPTIONAL FRONT COVER
PRESSURE SWITCH