Grounding – Furuno LCD DISPLAY MU-155C User Manual
Page 13
6
Port, cable and connectable equipment
Used cable
Port
Name
Name Type Code
No.
Standard/
Option
Connectable Equipment
12-24
VDC
Power
cable
MJ-A3SPF0017-
050Z
000-138-928
Standard Power
source
DVI-D
DVI
Cable
DVI-D/D
SINGLELINK5M
000-149-054
Option
PC, FAR-21X7 series,
FEA-2107
RGB1
3COX-2P-6C
5M
000-146-500
Option
RGB2
Analog
RGB
Cable
3COX-2P-6C
10M
000-146-501
Option
FCV-1200L/1200LM,
CH-250, CH-270,
CSH-5L/8L,
FSV-24/24S/30/30S,
GD/GP-280/380/680,
FR-1500 MK3 series,
FR-21X5 series,
Model 1833C series,
Model 1833C-BB series
VIDEO1
VIDEO2
VIDEO3
Prepare the following cable locally.
▪ Connector type: RCA (metal), both ends
▪ Cable length: shorter than 10 m
▪ 2.5C2V or 3C2V (Japan Industrial Standard, or the
equivalent) coaxial cable (Impedance: 75 Ω)
Conductor
S = 0.19 mm
∅
= 0.5 mm
2
Vinyl
Shield
Cable 3C2V
Insulator
sheath
Video cassette
recorder, CCD camera,
DVD player
Grounding
Fasten the ground wire (local supply) between the ground terminal on the display unit and
the ship’s superstructure. The length should be as short as possible.
Note:
Use a “closed-type” lug (
) to make the ground connection at the display unit. Do
not use an “open-type” lug (
).