Furuno FEA-2107 User Manual
1" color lcd 23.1" color lcd
SPECIFICATIONS
Remote Control Unit
RCU-015
RCU-016
1.5 m
5/
10
m
250V-TTYCS
250V-TTYCS/
MPYC
MU-201CE/
231CE
10/
20
/
30
m
10
/
20
/
30
m
2.5 m
10
/
20
/
30
m
LAN Adapter
EC-1010
24 VDC
1.5 m
100-230 VAC
Option
Shipyard Supply
Display Unit
Control Unit
ECDIS for 2nd station
Processor Unit
EC-1000C
HUB
HUB-100
AIS
Track Pilot *
AMWSS
Route Backup
GPS Navigator
Anemometer
Echo Sounder
Log/Dual Axis Log
Gyrocompass
Engine Control
Water Temp Indicator
Alarms
B Adapter
EC-1020
24 VDC
x8
x2
x8
5
m
Conning Monitor
Gyrocompass (Synchro)
Log (200 p/nm)
Alarms
Analog Sensors
Radar/ARPA*
HUB
HUB-100
INTERCONNECTION DIAGRAM
RCU-018
or
FAR-21x7 series
FAR-28x7 series
Standards
IMO Resolution A.817(19), IEC 61174 ed2
Display Unit
FEA-2107: MU-201CE, 20.1" color LCD, SXGA (1280 x 1024 pixels)
FEA-2807: MU-231CE, 23.1" color LCD, UXGA (1600 x 1200 pixels)
Operating System
Windows XP
Useable Charts
IHO/S-57 v.3 vector chart, ARCS raster chart, C-MAP CM93 ed3*
*available in the near future
Presentation Modes
True/Relative Motion Noth-up, True/Relative Motion Course-up
Relative Motion Head-up, Relative Motion Route-up
Display of data
Own ship :
Position, SOG, COG, Heading
Route :
Planned route, Monitoring route
ARPA targets :
Range, Bearing, Speed, Course, CPA and TCPA
Others :
EBL, VRM, Parallel index line, Cursor position, Navigation
and pilot data notebook
Route/Waypoint
Route: more than 100 routes
Waypoints: 200 waypoints /route
Voyage Calculation
The following data can be calculated
Range/Bearing to destination, TTG, ETA, Fuel consumption
Route Navigation Monitoring Off track, Waypoint, Arrival, Grounding, Depth
Alarms
Off track, Channel limit, Waypoint approach, Depth
Other Functions
Night/day presentation colors, ARPA target display, Radar overlay,
User chart function, Position optimization, MOB, Log book,
Pilot data function, Track control system (TCS)*
* Please contact the local dealers in your area for details.
Interface
Input/output
AIS :
IEC 61162-2 (ABM, BBM)
Radar signal :
Ethernet 100 Base-TX or RAW Video
Input
Gyrocompass :
IEC 61162-1 (HDT) or Synchro
SDME (Speed log) :
IEC 61162-1 (VBW) or Pulse type
EPFS :
IEC 61162-1 (GLL, GGA, VTG, ZDA, DTM)
Echo Sounder :
IEC 61162-1 (DBT, DPT)
Anemometer :
IEC 61162-1 (MWV)
Water temp Indicator : IEC 61162-1 (MTW)
Current Indicator :
IEC 61162-1 (VDR)
Output
Alarms :
Relay output
Printer :
Parallel
Power Supply
Display Unit:
100 - 230 VAC, 1 ø, 50/60 Hz
Processor Unit:
100 - 230 VAC, 1 ø, 50/60 Hz
LAN Adapter:
24 VDC
B Adapter:
24 VDC
Environment
(IEC 60945 test method)
Temperature
All Units:
-15˚C to +55˚C
Equipment List
Standard
1. Display Unit FEA-2107: MU201CE, FEA-2807: MU-231CE 1 unit
2. Control Head RCU-018 or
Trackball Control Unit RCU-015 (Specify when ordering) 1 unit
3. Processor Unit EC-1000C
1 unit
4. LAN Adapter EC-1010
1 unit
5. Power Supply Cable for Processor Unit, 1.5 m
1 pc
6. Power Supply Cable for Display Unit, 1.5 m
1 pc
7. DVI Cable between Display Unit and Processor Unit, 5 m
1 pc
8. Cable between Control Unit and Processor Unit, 10 m
1 pc
9. LAN Cable, 2 m
1 pc
10. Standard Spare Parts and Installation Materials
1 set
Option
1. LAN Adapter EC-1010
2. B Adapter EC-1020 for equipment with analog interface
3. Remote Control Unit RCU-016
4. Cable between Control Unit and
Remote Control Unit 03S9610, 1.5/10/20/30 m
5. Hub HUB-100
6. Radar Overlay Kit for FAR-21x5 series and FAR-28x5 series
7. Video Card for Conning Display Unit
8. Cable between Control Unit and Processor Unit, 20/30 m
9. DVI Cable between Display Unit and Processor Unit, 10 m
10. Armored LAN Cable OP03-186-10/20/30
11. Printer PP-510
12. USB-Parallel Printer Cable for PP-510
13. Hand Grip
14. Bracket
15. Connection Stand
16. Pedestal slim/standard Type
The future today with FURUNO's electronics technology.
9-52 Ashihara-cho, Nishinomiya City, Japan Phone: +81 (0)798 65-2111
Fax: +81 (0)798 65-4200, 66-4622 URL: www.furuno.co.jp
TRADE MARK REGISTERED MARCA REGISTRADA
Catalogue No. L-161b
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
TRADE MARK REGISTERED
MARCA REGISTRADA
05015U Printed in Japan
Ethernet
Ethernet
250V-TTYCS-1T
250V-
TTYCS-1
Serial
554 21.8"
570 22.4"
313 12.3"
471 18.5"
598 23.5"
590 23.2"
Hand Grip
(option)
92 3.6"
398 15.7"
308 12.1"
136 5.4"
180 7.1"
4- 4
54 2.1"
39 1.5"
110 4.3"
4- 4
160 6.3"
136 5.4"
180 7.1"
89 3.5"
50 2.0"
35 1.4"
110 4.3"
4- 4
160 6.3"
136 5.4"
180 7.1"
89 3.5"
50 2.0"
35 1.4"
110 4.3"
50
5
1
9.
9"
451 17.8"
35
287 11.3"
352 13.9"
Bracket
(option)
534 21.0"
526 20.7"
Hand Grip
(option)
490 19.3"
296 11.7"
420 16.5"
506 19.9"
110 4.3"
45
4
1
7.
9"
409 16.0"
35
287 11.3"
352 13.9"
Bracket
(option)
440 17.3"
470 18.5"
150
5.9"
150
5.9"
50
2.0"
486 19.0"
395 15.6"
10 0.4"
179 7.1"
6- 8
Display Unit
Processor Unit
Control Head
Trackball Control Unit
Remote Control Unit
RCU-015
2.4 kg 5.3 lb
RCU-016
2.4 kg 5.3 lb
EC-1000C
15 kg 33.1 lb
RCU-018
3.7 kg 8.2 lb
MU-201CE
18.3 kg 40.4 lb
MU-231CE
23.5 kg 51.8 lb
20.1" color LCD
23.1" color LCD
*Up to two LAN
adapters connectable
*Please contact the local dealers in your area for details.
Digitizer
Printer
PP-510
With 8 ports
With 18 ports
*Up to four systems can
be connected
58 669 02 20
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300
Fax: +1 360-834-9400
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K.
Phone: +44 2392-230303
Fax: +44 2392-230101
FURUNO FRANCE S.A.
Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00
Fax: +33 5 56 13 48 01
FURUNO ESPAÑA S.A.
Madrid, Spain
Phone: +34 91-725-90-88
Fax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00
Fax: +45 36 77 45 01
FURUNO NORGE A/S
Ålesund, Norway
Phone: +47 70 102950
Fax: +47 70 127021
FURUNO SVERIGE AB
Västra Frölunda, Sweden
Phone: +46 31-7098940
Fax: +46 31-497093
FURUNO FINLAND OY
Espoo, Finland
Phone: +358 9 4355 670
Fax: +358 9 4355 6710
FURUNO POLSKA Sp. Z o.o.
Gdynia, Poland
Phone: +48
Fax: +48 58 669 02 21