5 alarm kit – Furuno FR-2115-B User Manual
Page 53
4-14
4.5
Alarm Kit
The alarm kit mainly consists of a circuit board and connection cables, and provides alarm output
to ship's bridge alarm system.
Necessary parts: OP03-156 (Code no. 008-500-650)
Name
Type
Code No.
Qty
ALARM Board
03P9262
008-500-680
1
NH Connector Assy.
03-1990(9-9P)
008-500-700
1
NH Connector Assy.
03-1991(3P)
008-500-710
4
Cable Band
HP-3N
000-570-001
1
Cable Tie
CV-100
000-570-322
3
Pan-head Screw B
M3X8 C2700W
000-881-404
4
Pan-Head Screw B
M3X8 C2700W
000-881-447
1
Refer to the figure on the next page for parts location.
1. Open the processor unit.
2. Unfasten four screws to dismount the INT Board cover.
3. Fasten the ALARM Board to the processor unit with four M3X8 pan-head screws (supplied).
4. Connect the NH connector (9-9P, supplied) between J471 on the ALARM Board and J451
(EXT-BUZ) on the INT Board, passing it through the cable band and binding it with existing
cable tie.
5. Fasten the cable band (supplied) with a pan-head screw (M4X12, supplied) and attach two
cable ties (CV-100, supplied).
6. Connect a NH connector (3P, supplied) to each of J472, J473, J474 and J475 on the ALARM
Board.
7. Route the NH connectors along the cable ties and pass them through the cable clamp.
8. Close the INT board cover.
9. Close the processor unit.