3.7 Confirming Magnetron Heater Voltage

Magnetron heater voltage is adjusted at the factory. However, confirm that it is within the

prescribed rating.

Table 3-1 Magnetron heater voltage rating

Rating

FR-2115-B (12 kW) FR-2125-B (25 kW)

ST-BY, 0.125 nm

7.4 to 7.6 V

8.2 to 8.4 V

TX, max range

7.4 to 7.6 V

6.5 to 7.5 V

1. Press [RADAR MENU] [0] [0] [0] [2] [0] to open the INITIAL SETTING2 menu.

2. Press [5] to select both the 5. SCANNER STOPPED field and the TX option and press

[ENTER]. Disconnect connector P821 from the antenna unit.

3. Turn off screen brilliance.

4. Measure voltage between pins #12(+) and #5(-) on connector P801 on the RFC Board

(03P9243) in the antenna unit.

5. If the voltage is not within the rating shown in Table 3-1, adjust potentiometer VR1 on the

RFC Board.

6. Show the INITIAL SETTING 2 menu, press [5] to select ST-BY, and then press [ENTER].

J611

J821

J801

VR1

03P9243

Figure 3-5 RFC Board