beautypg.com

Harbor Freight Tools 93253 User Manual

Page 7

background image

SKU 92917 & 93253

For technical questions, please call 1-800-444-3353.

Page 7

Connect the air supply to the tool at the Air Plug (83). Set the regulator at the rec-
ommended

70 PSI to 100 PSI, and set not to go over the maximum 100 PSI.

Test the tool by depressing the nose against the workpiece without pulling the Trig-
ger (73).

The Tool must not cycle (fire). If it cycles (fires), stop immediately and

have it repaired by a qualified service technician.

Hold the tool away or off of the workpiece. The nose of the tool should return to its
original position. Squeeze the Trigger (73).

The tool should not cycle (fire). If the

tool fires, stop immediately and have it repaired by a qualified service technician.

Depress the nose against the workpiece and squeeze the Trigger (73).

The tool

must cycle (fire) only once. Release the Trigger and squeeze it again. The tool
must not cycle (fire).
With the Trigger held, carefully lift the nailer and press it
against the workpiece again.

The tool must not cycle (fire). If it fails to perform

in the manner explained in bold, have it repaired by a qualified service technician.

5.

6.

7.

8.

Loading Coil Nails

ALWAYS WEAR ANSI-APPROVED IMPACT SAFETY GOGGLES WHEN
RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL.
Other people in the work area must also wear ANSI-approved impact safety
goggles.

Warning! Make sure the Nailer is not attached to the air hose whenever loading
the tool.

NOSE

TRIGGER (73)

AIR PLUG (83)