Harbor Freight Tools 93253 User Manual
Page 6
SKU 92917 & 93253
For technical questions, please call 1-800-444-3353.
Page 6
Note: To connect this tool, we recommend you use Air Plug (83, not included). For smoother
operation and to extend the life-span of the tool, put 3-5 drops of pneumatic tool oil
in the attached Air Plug (83) before each use.
Unpacking
When unpacking, check to make sure all parts shown in the Parts List on page 13
are included. If any parts are missing or broken, please call Harbor Freight Tools at the
number on the cover of this manual as soon as possible.
Operation
For best service, you should incorporate an oiler, regulator, and inline filter, as
shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are all avail-
able at Harbor Freight Tools.
TO
ROOFING
NAILER
Testing the Full Sequential Safety Trip Mechanism
Warning: Even though the nailer should be empty during this procedure,
ALWAYS point the nailer at a piece of scrap wood when testing.
Make sure the tool is disconnected from the air supply.
Completely empty the Nail Canister (90) of nails.
The Nailer should not fire if the nose is not depressed against the workpiece.
Make sure the Trigger (73) and nose move freely, without sticking - see the illustra-
tion on the following page.
1.
2.
3.
4.
REV 11/05