beautypg.com

Operating information – Harbor Freight Tools Auto A/C Recovery / Recharge Machine 95951 User Manual

Page 10

background image

Page 10

SKU 95951

For technical questions, please call 1-800-444-3353.

lp gauge hp gauge

Bp gauge

lp valve

hp valve

led display

+

Start/Stop

Refilling

vacuumize

indicators

Circulate

Recovering

Control panel gauges

Please refer to the drawing on page 9 for Control Panel items.
hp gauge:

1.

Displays pressure of the high pressure end of the auto A/C system.

lp gauge:

2.

Displays pressure of the low pressure end of the auto A/C system.

Bp gauge:

3.

Displays pressure of the refrigerant tank of this machine.

indicator lights

Recovering:

1.

When lighted, indicates that the machine is performing the recovery

operation.
vacuumize:

2.

When lighted, indicates that the machine is generating vacuum.

Refilling:

3.

When lighted, indicates that the machine is refilling the auto system. New

refrigerant is being added.
drain:

4.

When lighted, indicates that the machine is draining used cooling oil from

the auto A/C system.
hp / Bottle Full:

5.

During the Recovery process when the light is on, it indicates either

that the HP pressure has reached or exceeded 240 PSI. The Recovery process

will halt until the pressure has automatically lowered to 180 PSI or less. If the pres-

sure is within safe bounds and this light comes on, it indicates that the Refrigerant

Tank is full, weighing over 14 kg. The Refrigerant Tank must be partially emptied to

continue the recovery process.

opeRAting inFoRMAtion

REV 09h