Summary of A/V Notifications

(cont’d)

Alpha Display Keypads

SOUND CAUSE

DISPLAY

LOUD,
INTERRUPTED*
Keypad & Ext.

FIRE ALARM.

FIRE is displayed; descriptor of zone in alarm is
displayed. If a fire alarm is manually activated, zone
number 95 will be displayed.

LOUD,
CONTINUOUS*
Keypad & Ext.

BURGLARY/AUDIBLE
EMERGENCY ALARM.

ALARM is displayed. If programmed, descriptor of
zone in alarm is also displayed

ONE SHORT
BEEP
(not repeated)
Keypad only

a. SYSTEM DISARM.

b. SYSTEM ARMING ATTEMPT

WITH AN OPEN ZONE.

c. BYPASS VERIFY.

a. DISARMED/READY TO ARM is displayed.

b. Number and descriptor of open protection zone is

displayed.

c. Numbers and descriptors of the bypassed zones are

displayed (One beep is heard for each zone
displayed). Subsequently, the following is
displayed: DISARMED BYPASS /Ready to Arm.

ONE SHORT
BEEP
(once every 40
seconds)
Keypad only

a. SYSTEM IS IN TEST

MODE.

b, LOW BATTERY AT A

TRANSMITTER.

c. SYSTEM WILL AUTOARM

WITHIN 10 MINUTES

a. Opened Zone identifications will appear.

b. LO BAT displayed with description of

transmitter.

c. No special display.

TWO

SHORT

BEEPS
Keypad only

ARM AWAY or MAXIMUM.

ARMED AWAY or MAXIMUM displayed. Red
ARMED indicator lit.

THREE SHORT
BEEPS
Keypad only

a. ARM STAY, NIGHT-

STAY, OR INSTANT.

b. ZONE OPENED WHILE

SYSTEM IS DISARMED.

a. ARMED STAY or ARMED INSTANT displayed.

Red ARMED indicator lit.

b. CHIME displayed, descriptor of open protection

zone will be displayed if the [

✱] key is pressed.

RAPID
BEEPING
Keypad only

a. TROUBLE.

b. MEMORY OF ALARM.

c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE

FAIL.

a. CHECK displayed. Descriptor of troubled

protection zone is displayed.

b. FIRE or ALARM is displayed; descriptor of zone

in alarm is displayed.

c. SYSTEM LO BAT displayed.

d.

BELL FAILURE is displayed.

SLOW
BEEPING
Keypad only

a. EXIT DELAY WARNING

(if programmed).

b. ENTRY DELAY

WARNING.

a. ARMED AWAY or MAXIMUM is displayed

along with You May Exit Now.

b. DISARM SYSTEM OR ALARM WILL OCCUR

is displayed. Exceeding the delay time without
disarming causes an alarm.

* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.