Functions of the Keypads

(cont’d)

NOTE: The functions printed directly on the
keys indicate their primary purpose; the
functions printed under some of the keys (shown
in brackets under the respective key), indicate
their alternate or secondary purpose.

1. DISPLAY

WINDOW

Alpha Display Keypads: 2-line, 32-
character Liquid Crystal Display (LCD)
keypads that display protection point
identification, system status, and
messages.

Fixed-Word Display Keypads:

Display protection zone ID and system
status messages using pre-designated
words in the LCD display area.

2.

1

OFF

Disarms burglary portion of

the system, silences alarms and audible
trouble indicators, and clears visual
display after problem's correction.

[RECORD] On Voice keypads, used in
conjunction with the FUNCTION and
VOICE keys to record up to a 2.5-
minute message.

3.

2

AWAY

Arms the entire burglary

system, perimeter and interior.

[VOLUME] On Voice keypads, used in
conjunction with the FUNCTION and
desired volume control keys

↑ [3] or

[6] to adjust the volume of a recorded
message or voice system status.

4.

3

STAY

Arms perimeter portion of

burglary system only. Interior
protection is not armed, allowing
movement within premises without
causing an alarm. If pressed twice in
succession, arms system in Night-Stay
mode.

[PLAY] On Voice keypads, used in
conjunction with the FUNCTION and
VOICE keys to play the recorded
message.

[

↑↑↑↑ ] On Voice keypads, used in

conjunction with the FUNCTION and
VOLUME keys to raise the message
and voice system status volume.

5.

4

MAX

Arms the entire burglary

system, perimeter and interior, but
without entry delay feature. Entering
via an entry/exit door will cause an
alarm.

6. 5

TEST

Tests the system and alarm

sounder if disarmed. Refer to Testing
The System
section for test procedures.

7.

6

BYPASS

Removes individual

protection zones from being monitored
by the system.

[

↓↓↓↓ ] On Voice keypads, used in

conjunction with the FUNCTION and
VOLUME keys to lower the message
and voice system status volume.

8.

7

INSTANT

Arms in manner similar to

the STAY mode, but without the entry
delay feature.

Entering via an entry/exit door will
cause an alarm.

9.

8

CODE

Used to assign additional user

codes and attributes for other users of
the system.

10. 9

CHIME

Turns CHIME mode on and

off. When on, the opening of windows or
doors while the system is disarmed will
sound 3 beeps at the keypad(s).