A. listings and code approvals, B. description of the imperial gas log set – Hearth and Home Technologies FI42SL User Manual
Page 3
11/12
33734 Rev K
3
A. Listings and Code Approvals
The Imperial Series Gas Log Set has been tested and listed in the U.S. in accordance with
ANSI Z21.60-1996 (Gas Log
Set). In Canada the Imperial Series Gas Log Set has been tested and approved in accordance with
CGA 2.26-M96. It has
been listed by Underwriters Laboratories Inc. for installation and operation in the United States and Canada as described
in these Installation and Operating Instructions. All components are UL, AGA, CGA or CSA safety certifi ed.
Check with your local building code agency prior to installing this appliance to ensure compliance with local codes, includ-
ing the need for permits and follow-up inspections. In the absence of local codes, comply with the
National Fuel Gas
Code, ANSI Z223.1-Latest Edition in the U.S.; in Canada, the CAN/CGA B149 Installation Codes. If any assistance is
required during installation, please contact your dealer for more information or visit: www.hpba.org/staysafe.
HEATILATOR® is a registered trademark of Hearth & Home Technologies Inc.
WARNING!
This Heatilator appliance and its components are designed to be installed and operated as a system.
Any alteration to or substitution for items in this system, unless allowed by these installation instruc-
tions, will void the Underwriters Laboratories listing and may void the product warranty. It may also
create a hazardous installation. Read through these instructions thoroughly before starting your
installation and follow them carefully throughout your project.
WARNING!
Do not use this appliance if any part has been under water. Immediately call a qualifi ed service techni-
cian to inspect the appliance and to replace any part of the control system and any gas control which
has been under water.
B. Description of the Imperial Gas Log Set
The HEATILATOR® Imperial Gas Log Set
consists of the following:
1. Burner/Hearth Assembly
2. Grate Assembly
3. Four Fiber Logs
Optional components include:
RC-BATT-HTL Remote Control (M-Series only)
Imperial Series Nomenclature
Tools and building supplies nor-
mally required for installation:
Pliers
Phillips screwdriver
Tape measure
Crescent wrenches
Non-corrosive leak-check solution
Note: The illustrations and diagrams used throughout
these installation instructions are not drawn to
scale.
Fi42ML
Logset Order Code Number
Fi
Imperial Series Log Set
36
36” Log Set
42
42” Log Set
M
Intermittent Pilot
S
Safety Pilot Manual Valve
No Suffi x
Natural Gas
L
Propane Gas