Hearth and Home Technologies FI42SL User Manual
Page 12
12
33734 Rev K
11/12
G. Glass Doors
If your fi replace is equipped with a glass door, the glass doors should be in the full open position when the appliance is
operating. Operating the fi replace with the glass doors closed will block the radiant heat output of the fi replace and may
cause incomplete combustion of the natural or propane gas fuel.
IMPORTANT!
Always ensure that the wire fi replace screen is closed when the fi replace is operating.
Your gas logs require little care. Keep the burner assembly, logs and burner area surrounding the logs clean by vacuum-
ing or brushing with a dry paint brush at least twice a year.
• Always turn off the gas to the pilot before cleaning. For relighting, refer to lighting instructions located on
pages 10 and 11.
• Always keep the appliance clear and free from combustible materials, gasoline, and other fl ammable vapors
and liquids.
• Never obstruct the fl ow of combustion and ventilation air. Keep the front of the appliance clear of all obstacles
and materials.
• Leave clearance of at least 36” from the front of the fi replace.
• The air shutter should not be blocked.
CAUTION:
The logs can get very hot. Handle only when they
are cool.
CAUTION:
After burning, the log becomes fragile, so take care
in handling.
The fi replace venting system is designed and constructed to develop a positive fl ow adequate to remove fl ue gases to the
outside atmosphere. See vented fi replace installation instructions.
1. A spillage test must be made before the installed appliance is left with the consumer.
a. Close all doors and windows in the home.
b. Light the log set.
c. After three minutes, test with a smoke match, smoke candle, stick incense, or cigarette 1” below the top
of the opening (lintel) moving across the full width. See Figure 16. If spillage (smoke drawn into the room)
occurs, it will most likely be near the top, outside corners.
Figure 16 - Checking for Spillage
H. Cleaning
I. Inspecting the Venting System