beautypg.com

Hearth and Home Technologies A42C User Manual

Page 8

background image

8

• The

fi rst three or four fi res should be of moderate size to

allow the oils and binders to be burned from the fi replace
and the refractory and paint to cure. You may notice
an industrial odor the fi rst few fi res. This is considered
normal.

• Use well-seasoned wood (see Section 2.N.).
• Open

the

fl ue damper to a fully open position.

• Place crumpled or twisted paper under the fi replace

grate.

• Loosely arrange kindling or small pieces of wood to form

a ‘tent’ on the fi replace grate.

• Pre-warm

the

fl ue to establish a draft to help reduce

smoke spillage during start-up. Hold a rolled up piece
of burning newspaper under the fl ue damper for a few
moments.

• Light the crumpled paper to ignite the kindling.
• Add small pieces of wood until a hot bed of embers has

been established.

• Add a minimum of three average size pieces of split

fi rewood, placed to allow combustion air and fl ames
between them.

C. Starting a Fire

NOTICE: You must establish a good draft to prevent smoke
spillage into the room.
WARNING! Risk of Fire! Keep combustible materials,
gasoline and other fl ammable vapors and liquids clear of
the fi replace.
DO NOT:
• store

fl ammable materials close to the fi replace

• use gasoline, lantern fuel, kerosene, charcoal lighter

fl uid or similar liquids to start or “freshen up” a fi re in this
fi replace.

Keep all fl ammable liquids well away from the fi replace while
it is in use. Combustible materials may ignite.

B. Seasoned Wood

Properly seasoned wood is important for successful
operation of your fi replace. Most woodburning fi replace
problems are caused by burning wet, unseasoned wood.

Seasoned fi rewood is wood that is cut to size, split and air
dried to a moisture content of around 20%.

Imagine a wooden bucket that weighs about eight
pounds. Fill it with a gallon of water, put it in the fi replace
and try to burn it. This sounds ridiculous but that is exactly
what you are doing if you burn unseasoned wood.

A tree cut down a year ago and not split is likely to have
almost as high a moisture content now as it did when it
was cut.

Please refer to Section 2.N. for more detail.

CAUTION!

Odors and vapors released during initial

operation may be irritating to sensitive individuals.
Open windows for air circulation.

D. Grate

This fi replace is designed to be used with the grate sup-
plied with this unit or one approved by HHT. The grate will
break down over time and will need occasional replace-
ment.

WARNING! Risk of Fire! Use only the factory-supplied
integral grate.
• Keeps logs in place.
• Allows proper air circulation around the fi re.

E. Firescreen

The fi rescreen is provided to control sparks. Keep it
closed when the fi replace is in use.
WARNING! Risk of Fire or Burns!
• Screen will not prevent burning materials from falling

out.

• Screen pulls or handles may be hot.

F. Flue Damper

• Refer to Figure 2.1 for location of control.
• Must be in fully open position (handle up toward the top

of the fi replace) during operation of the fi replace.

• Before

lighting

the

fi replace, verify fully open position by

looking up from the inside of the fi replace.

WARNING! Risk of Fire and Asphyxiation! Open
damper prior to operating fi replace. A closed damper
overfi res the fi replace and spills smoke and fl ames
into the room.

G. Refractory

• The refractory is supplied to contain heat and provide

an attractive interior.

• It will break down over time and will need occasional

replacement. Small hairline cracks and discoloration are
normal and do not affect its safety.

• (See refractory maintenance Section 3.C.)

WARNING! Risk of Fire! DO NOT burn fi replace with-
out refractory. Use only refractory supplied by Hearth &
Home Technologies, Inc.

Heatilator • A36C & A42C • 28396 • Rev AG • 11/08

This manual is related to the following products: