Maintainance and Service

Figure 3.1 Chimney & Termination Cap Cleaning

A. Disposal of Ashes

Frequency: When they reach bottom of grate
By: Homeowner

WARNING! Risk of Fire! Ashes could contain hot em-
bers.

• Place ashes in a metal container with a tight-fi tting lid.
• The closed container should be placed on a

noncombustible fl oor or on the ground, well away from
all combustible materials, pending fi nal disposal.

• If the ashes are disposed of by burial in soil or otherwise

locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled

B. Chimney Inspection/Cleaning

Frequency: At least twice a year during heating season
or as recommended by a certifi ed chimney sweep
By: Certifi ed chimney sweep
WARNING! Risk of Fire! Ignited creosote is extremely
HOT. Prevent creosote buildup.

Refer to Figure 3.1 to remove/reinstall termination caps.

Creosote - Formation and Need for Removal

When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the rela-
tively cool chimney fl ue of a slow-burning fi re. As a result,
creosote residue accumulates on the fl ue lining. When
ignited this creosote makes an extremely hot fi re.

WARNING! Risk of Fire! A chimney fi re can permanently
damage your chimney system and nearby structures.

In the event of a chimney fi re, Hearth & Home Technolo-
gies Inc. recommends

• replacement of the chimney, and
• inspection of the adjacent structure to the provisions of

NFPA Level III inspection criteria.

The chimney shall be inspected at least twice a year
during the heating season to determine when a creosote
buildup has occurred.

When creosote has accumulated it shall be removed to
reduce the risk of a chimney fi re.

Heatilator • A36C & A42C • 28396 • Rev AG • 11/08

Chimney

Remove 4 screws
and lift top pan off.

Cap

Slip

Section

ST375

Square

Termination Cap

Cap

Remove screws,
lift top cover.

Top Cover

TR344/TR342

Round

Termination Cap

Chase

Cap

1. Remove the 4 screws.
2. Remove the screen.
3. Remove the baffle.

TS345/TS345P

Square

Termination Caps

TCT375

Terra Cotta

Termination Cap

Remove 2 screws from
the front and back and
lift the top off.

This manual is related to the following products: