Specifications – Hafler SR2300 User Manual
Page 10
– 8 –
All measurements taken at Normal Operating Conditions (i.e. 1/8th rated output power) unless noted otherwise.
POWER RATING:
8
Ω
20-20kHz @ 0.1% THD
300W x 2 CH
600W x 2 CH
4
Ω
20-20kHz @ 0.2% THD
300W x 2 CH
600W x 2 CH
2
Ω
20-20kHz @ 0.3% THD
300W x 2 CH
600W x 2 CH
70V
20-20kHz @ 0.2% THD
600W x 1 CH
1200W x 1 CH
100V
20-20kHz @ 0.2% THD
600W x 1 CH
1200W x 1 CH
Bridged 8
Ω
20-20kHz @ 0.2% THD
600W x 1 CH
1200W x 1 CH
Bridged 4
Ω
20-20kHz @ 0.3% THD
600W x 1 CH
1200W x 1 CH
FREQUENCY RESPONSE:
10Hz-20kHz +/–0.1dB
10Hz-20kHz +/–0.1dB
0.2Hz-100kHz +/–3dB
0.2Hz-100kHz +/–3dB
INPUT SENSITIVITY:
8
Ω
0.9V
1.3V
4
Ω
0.6V
0.9V
2
Ω
0.45V
0.6V
MAX. INPUT:
3.0V
3.0V
SIGNAL-TO-NOISE:
>100dB “A” WGT
>100dB “A” WGT
CMMR:
>75dB at 1kHz
>75dB at 1kHz
INPUT IMPEDANCE:
47k
Ω
per phase balanced
47k
Ω
per phase balanced
DAMPING FACTOR:
>500
>500
POWER/THERMAL REQUIREMENTS:
Idle Condition*
55W
70W
“U” version
860mA @ 115VAC
1.0A @ 115VAC
“CE” version
430mA @ 230VAC
500mA @ 230VAC
Thermal Dissipation
190 BTU/hr
240 BTU/hr
Normal Operating Condition
(1/8 rated power, pink noise)
280W
490W
“U” version
3.5A @ 115VAC
5.8A @ 115VAC
“CE” version
1.7A @ 230VAC
2.9A @ 230VAC
Thermal Dissipation
680 BTU/hr
1160 BTU/hr
Worst Case
(1/3 rated power, pink noise)
550W
1000W
“U” version
6.6A @ 115VAC
12A @ 115VAC
“CE” version
3.3A @ 230VAC
5.9A @ 230VAC
Thermal Dissipation
1200 BTU/hr
2080 BTU/hr
FUSE:
"U" version (115VAC nominal)
7A, 3AG Slo-Blo, 1 ea.
15A, 3AG Slo-Blo, 1 ea.
"CE" version (230VAC nominal)
T5A, 5 x 20mm, 1 ea.
T6.3A, 5 x 20mm, 1 ea.
MAINS POWER VOLTAGE:
"U" version
100-140VAC, 50-60Hz
100-140VAC, 50-60Hz
"CE" version
200-265VAC, 50-60Hz
200-265VAC, 50-60Hz
SR2600
SR2300
Specifications
*both channels driven at rated power