Extension cords, Symbology – Harbor Freight Tools 31810 User Manual

Page 6

background image

SKU 31810

For technical questions, please call 1-800-444-3353.

Page 6

The tool must be plugged into an

3.

appropriate outlet, properly installed

and grounded in accordance with all

codes and ordinances. The plug and

outlet should look like those in the

preceding illustration.

(See 3-Prong

Plug and Outlet.)

Extension Cords

Grounded

1.

tools require a three wire

extension cord. Double Insulated

tools can use either a two or three

wire extension cord.
As the distance from the supply outlet

2.

increases, you must use a heavier

gauge extension cord. Using exten-

sion cords with inadequately sized

wire causes a serious drop in voltage,

resulting in loss of power and pos-

sible tool damage.

(See Table a.)
The smaller the gauge number of the

3.

wire, the greater the capacity of the

cord. For example, a 14 gauge cord

can carry a higher current than a 16

gauge cord.

(See Table a.)

When using more than one exten-

4.

sion cord to make up the total length,

make sure each cord contains at

least the minimum wire size required.

(See Table a.)
If you are using one extension cord

5.

for more than one tool, add the

nameplate

amperes and use the sum

to determine the required minimum

cord size.

(See Table a.)

If you are using an extension cord

6.

outdoors, make sure it is marked with

the suffix “W-A” (“W” in Canada) to

indicate it is acceptable for outdoor

use.

Make sure the extension cord is prop-

7.

erly wired and in good electrical con-

dition. Always replace a damaged

extension cord or have it repaired by

a qualified electrician before using it.
Protect the extension cords from

8.

sharp objects, excessive heat, and

damp or wet areas.

RECOMMENDED MINIMUM WIRE

gaUgE FOR EXTENSION CORDS*

(120/240 VOLT)

NaMEPLaTE

aMPERES

(at full load)

EXTENSION CORD

LENgTH

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TaBLE a

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

a

Amperes

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)