beautypg.com

Control board alarms (ea and ed), B. service chart, No operation – Hoshizaki REFRIGERATED PREP TABLE WITH RAISED RAIL 73168 User Manual

Page 33

background image

33

Problem

Possible Cause

Remedy

[1] The unit will not

start.

a) Power Supply

1. Unplugged, off,

blown fuse, or tripped
or defective circuit
breaker.

1. Turn on, replace, or check

and reset. Call electrician if
breaker trips repeatedly.

2. Loose connection.

2. Tighten.

3. Not within

specifications.

3. Refer to nameplate and

correct.

b) Cord and Plug

1. Defective.

1. Replace.

c) Control Switch

1. "OFF" position.

1. Move to "ON" position.

2. Bad contacts.

2. Check for continuity and

replace.

d) Transformer

1. Open coil winding.

1. Check continuity and

replace.

e) Wiring to Control Board 1. Loose connections or

open.

1. Check for continuity and

replace.

f) Control Board

1. In alarm.

1. See "III.A. Alarm Signals."

2. Defective.

2. Replace.

[2] Cabinet, rail, or

condenser fan will
not start.

a) Fan Motor

1. Motor winding open.

1. Replace.

2. Bearing worn out.

2 Replace.

3. Wiring to fan motor.

3. Check for loose or open

connection, and replace.

4. Fan blade bound.

4. Check and replace.

b) Evaporator Fan, Rail

Fan, or Compressor
Relay

1. Bad contacts.

1. Check for continuity and

replace.

2. Coil winding open.

2. Replace.

c) Control Board

1. Defective.

1. Replace.

[3] Compressor will

not start or stops
operating.

a) Compressor Relay

1. Bad contacts.

1. Check for continuity and

replace.

b) Compressor Control

Relay

1. Bad contacts.

1. Check for continuity and

replace.

2. Open winding.

2. Replace.

c) Start Relay

1. Bad contacts.

1. Replace.

2. Coil winding open.

2. Replace.

d) Start Capacitor

1. Defective.

1. Check and replace.

e) Wiring to Compressor

1. Loose connection(s).

1. Tighten.

2. Faulty.

2. Check continuity and

replace.

7. Control Board Alarms (EA and ED)

"EA" is displayed when an EEPROM write error is detected. "ED" is displayed when an
EEPROM verification or read error is detected.

Reset Options
Replacing the control board with a functioning control board will eliminate this alarm
condition.

B. Service Chart

1. No Operation