System Unit Rack

Dimensions (H x W x D)
(with bezel)

6.94 x 19.0 x 26.5 in (17.6 x 48.3 x 67.3 cm)

Weight
(approximate)

Maximum
(all hard drives, power
supplies, and processors
installed)

100.0 lb (45.4 kg)

Minimum
(one hard drive, power
supply, and processor
installed)

71.0 lb (32.2 kg)

Input Requirements
(per power supply)

Rated Line Voltage

90 - 132 VAC,
180 - 264 VAC

Rated Input Current

10 A (at 100 VAC),
7.8 A (at 200 VAC)

Rated Input Frequency

47 to 63 Hz

Rated Input Power

964 W (at 100 VAC),
1412 W (at 240 VAC)

BTU Rating

Maximum

3355 BTU/hr (at 100 VAC),
4914 BTU/hr (at 200 VAC)

Power Specifications

To review typical system power ratings use the Power Calculator which
is available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/Power%20
Calculator%20Catalog.xls

- Click on the system of interest. Example: DL580 G5
- Follow the instructions of the next screens.

Power Supply Output
(per power supply)

Rated Steady-State
Power

800 W (at 100 VAC),
1200 W (at 200 VAC)

Maximum Peak Power

800 W (at 100 VAC),
1200 W (at 200 VAC)

System Inlet
Temperature

Operating

10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.

Altitude

Operating

3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).

QuickSpecs

HP ProLiant DL580 Generation 5

Technical Specifications

DA - 12770 Worldwide QuickSpecs — Version 18 — 7.18.2008

Page 44