OPERATION INSTRUCTIONS

1. Before use, add a few drops of

pneumatic tool oil (not included) into

the Inlet.

2. Attach the Air Coupler (61) to Air

Inlet using pipe thread seal tape (not

included)

. Then connect the 3/8” Air

Source Hose to the Nailer.

3. Set the working air pressure on the

regulator to between 60 and 100 PSI.

Do not exceed 100 Max. PSI.

4. Set the Adjusting Dial (46) to match

the corresponding size (1/2”, 5/8”,

3/4”, 7/8” or 1”) of the fasteners

loaded in the Nailer.

Note: When changing pin size, turn the

Adjusting Dial to the new depth size

BEFORE inserting the new pins.

5. Slide the Safety (60) to the side so

that the Trigger (27) will function.

When ready, press down on the

Trigger (27) to operate.

6. Test before first use by driving nails

into a sample piece of wood. If the

fasteners do not achieve the desired

penetration, adjust the air pressure

to a higher setting until desired

penetration is achieved.

7. Always make sure the Bracket (40)

is flush against the workpiece during

use. Always release the Trigger (27)

once the fastener is driven into the

workpiece.

8. When ready to operate the Nailer,

press down on the Trigger (27). Make

sure the Nailer does not cycle during

use. Never use the Nailer if a cycle

occurs.

9. In case of a fastener jam, take your

finger off the Trigger (27). Rotate the

Trigger Lock/Safety (60) clockwise

or counter-clockwise. For instance,

a “6 o-clock” position will lock the

Trigger (27) and the tool will not fire.

However, “3 o-clock” and “9 o-clock”

positions unlock the Trigger (27),

allowing the tool to fire.

Note: There is no contact safety for the

Trigger (27). When the Trigger Lock/

Safety (60) is disengaged, the Nailer

will fire.

10. Turn off the air supply and

disconnect the Nailer from the

regulator. Open the Nozzle (40) and

clear the jammed fasteners with a

pair of pliers (not included).
If a jam occurs inside the magazine,

depress the upper tip of the Click

Lever (59). The Side Cover (34)

will pop open. If needed, open the

Nozzle (40) to help clear the jam.

Once the jam is cleared, push the

Side Cover (34) back into place and

latch tight using the Click Lever (59).