beautypg.com

Thermal protector, Lubrication, The agitator brush roll – Hoover Bagless Upright Vacuum Cleaner User Manual

Page 12: Edge groomer replacement

background image

12

3-24

3-25

The agitator brush roll

When to replace

When agitator brushes are worn, the
agitator should be replaced.

To check condition of brushes,

discon-

nect cleaner from electrical outlet.

Move edge of a card across bottom
plate while turning agitator. To maintain
cleaning effectiveness, replace agitator
if brushes do not touch card.

What to buy

Your cleaner requires either a 13” or 15”
agitator. When purchasing a new agita-
tor, ask for one of the following:

13” -

HOOVER part No. 48414110

15”

- HOOVER part No. 48414115.

How to replace

Disconnect cleaner from electrical
outlet.

Remove bottom plate, belt and agitator
following directions in “The belt” section
beginning with Fig. 3-18.

Discard old agitator.

Continue following the directions in “The
belt” section to reposition belt, new
agitator and bottom plate.

Installing groomers

Lift off both old edge groomers and slide
new edge groomers into position as
shown.

Reposition bottom plate and secure with
(4) Phillips head screws.

Thermal protector

An internal thermal protector has been
designed into your cleaner to protect it
from overheating.

When the thermal protector activates,
the cleaner will stop running.

If this

happens, proceed as follows:

1.

Turn the cleaner OFF and discon-

nect it from the electrical outlet.

2. Check secondary and final filters for

dirt accumulation.

3. Refer to “Clearing blockages”

section.

4.

When cleaner is unplugged and

the motor cools for 30 minutes,

the

thermal protector automatically resets
and cleaning may continue.

If the thermal protector continues to
activate after following the above steps,
your cleaner may need servicing

(see“Service” section).

Lubrication

The motor is equipped with bearings
that contain sufficient lubrication for the
life of the motor. The addition of lubricant
could cause damage.

Therefore, do not

add lubricant to motor bearings.

The agitator brush roll is equipped with
two ball bearings that should be lubri-
cated periodically by a Hoover Factory
Service Center or an Authorized Hoover
Warranty Service Dealer (Depot).

Edge groomer
replacement

When to replace

The edge groomers, located on both
sides of the nozzle, should be replaced
when they are worn.

What to buy

When purchasing edge groomers, ask
for HOOVER

part No. 39511004.

How to replace

Disconnect cleaner from electrical
outlet.

Remove bottom plate as described in
“The belt” section (Fig. 3-18).