Framing & Clearances

G

F

E

A

C

Across a
corner

H

As a
room
divider

D

48 in.

(1219 mm)

minimum

A

Along a wall

A

B

5/8 in. (16 mm) all
configurations

H

1/2 in. (13 mm) min. air
space from fireplace to
combustible materials.

Note:

Note: In addition to these

framing dimensions,
also reference the
following sections:
• Clearances (Section

6.B.)

• Mantel Projections

(Section 11.E.)

• Fireplace Dimensions

(Section 13.A.)

H

B

In an exterior chase
or projecting into a
garage

A

Note: Measurements are FRAMING dimensions only and do
not include drywall either in the cavity or on the interior walls.

I

I

Figure 6.1 Fireplace Locations (Framing dimensions shown)

A. Select Fireplace Location

Model

A

B

C

D

E

F

G

H

I

EL36

inches

42

50

67 7/8

59 1/2

34

14

48

21 1/2

12 in. (305 mm)
Minimum from FP
opening to any
perpendicular wall.

mm

1067

1270

1724

1511

864

356

1219

546

EL42

inches

48

56

73 7/8

65 1/2

37 1/4

14

52 1/4

21 1/2

mm

1219

1422

1876

1664

946

356

1327

546

Heatilator • EL36/EL42 • 4044-132 • Rev V • 11/08