B. Clearances

Figure 3.2 Clearances to Mantels or other Combustibles
above

Appliance

Fire Risk.
• Locate and install appliance to all clearance

specifi cations in manual.

Fire Risk.

Odor Risk.

• Clearance to combustible material under the

insert is 1/4 inch (0.6 cm).

• Use leveling legs to raise insert minimum

1/4 inch above combustible material or outer
wrap of factory built fi rebox.

WARNING

WARNING

MEASUREMENTS FROM

TOP EDGE OF UNIT

12 in. MIN.

12 in. MAX.

MANTEL

EXHAUST

VENT PIPE

INLET AIR

VENT PIPE

12 IN. MAX.

MANTEL

15 IN. MIN.

TOP OF DOOR

Figure 3.3 Clearances to Mantels or other Combustibles above
Appliance