EMI and Flush Strike Interlocks (optional)
The optional EMI or Flush Strike Interlocks are
provided with a combination mechanical lock and
electric contact. They are to be used with existing
doors.
The interlock:
• Prevents the lift from running if the door is
not closed.
• Prevents the door from being opened if the
platform is not at the landing.
• Unlocks when the lift is on the landing limit
switch.
Flush Strike Interlock
Refer to the instructions inside the strike box for
mounting requirements.
EMI Interlock
1) Position interlock to door jamb and mark
mounting holes.
2) Fasten Interlock to door jamb with #8 wood
screws.
3) Route 4-conductor Interlock cable thru hole in
top of interlock and make wire connections.
4) Attach door keeper and emergency key plates
to hoistway door.
.
14
A length of multi‐conductor wire will need to be ran
from the bottom of the lift tower to the interlocks.
Consult local codes for type and mounting
requirements. After wiring is completed, the wiring
harness must be plugged into it appropriate
receptacle on the controller (ref pg 5).
Wiring Connections
Flush Strike
Lift Harness
Yellow / *Black
Black
Yellow / *Purple
Green
White
White
Orange
Orange
Blue
Blue
Brown
Brown
*Colors when used on a DC (battery)
powered lift option.
EMI
Lift Harness
Black (A)
Black
Black (B)
Green
Yellow (C)
White
Yellow (D)
Orange
N/A
*Blue
N/A
*Brown
*Must be tied together when using an EMI
Interlock.