Fine tuning functions – Hitachi SJ100 User Manual
Page 199
Parameter Settings for Keypad Entry
Appendix B
B–6
Fine Tuning Functions
“B” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
-FE
(Europe)
-FU
(USA)
–FR
(Japan)
B_01
Selection of automatic restart
mode
00
00
00
B_02
Allowable under-voltage power
failure time
1.0
1.0
1.0
B_03
Retry wait time before motor
restart
1.0
1.0
1.0
B_12
Level of electronic thermal
setting
Rated
current for
each
inverter
Rated
current for
each
inverter
Rated
current for
each
inverter
B212
Level of electronic thermal
setting, 2nd motor
Rated
current for
each
inverter
Rated
current for
each
inverter
Rated
current for
each
inverter
B_13
Electronic thermal characteristic
01
01
00
B213
Electronic thermal characteristic,
2nd motor
01
01
00
B_21
Overload restriction operation
mode
01
01
01
B_22
Overload restriction setting
Rated
current x
1.25
Rated
current x
1.25
Rated
current x
1.25
B_23
Deceleration rate at overload
restriction
1.0
1.0
1.0
B_31
Software lock mode selection
01
01
01
B_81
[FM] terminal analog meter
adjustment
80
80
80
B_82
Start frequency adjustment
0.5
0.5
0.5
B_83
Carrier frequency setting
5.0
5.0
12.0
B_84
Initialization mode (parameters
or trip history)
00
00
00
B_85
Country code for initialization
01
02
00
B_86
Frequency scaling conversion
factor
1.0
1.0
1.0
B_87
STOP key enable
00
00
00
B_88
Restart mode after FRS
00
00
00