beautypg.com

Symbology – Harbor Freight Tools DRILL MASTER 96526 User Manual

Page 8

background image

Page

SKU 96526

For technical questions, please call 1-800-444-3353.

When using more than one extension cord to make up the total length, make

sure each cord contains at least the minimum wire size required.

(See table A.)

if you are using one extension cord for more than one tool, add the nameplate

amperes and use the sum to determine the required minimum cord size.

(See table A.)
if you are using an extension cord outdoors, make sure it is marked with the

suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.
Make sure the extension cord is properly wired and in good electrical condition.

Always replace a damaged extension cord or have it repaired by a qualified

electrician before using it.
Protect the extension cords from sharp objects, excessive heat, and damp or wet

areas.

RECOMMEnDED MInIMuM WIRE gAugE FOR EXtEnSIOn CORDS*

(120/240 VOLt)

nAMEpLAtE

AMpERES

(at full load)

EXtEnSIOn CORD LEngtH

25 Feet

50 Feet

75 Feet

100 Feet

150 Feet

0 – 2.0

1

1

1

1

16

2.1 – 3.4

1

1

1

16

14

3.5 – 5.0

1

1

16

14

12

5.1 – 7.0

1

16

14

12

12

7.1 – 12.0

1

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

tABLE A

* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

Symbology

Double insulated

V~

Volts Alternating Current

Canadian Standards Association

A

Amperes

Underwriters Laboratories, inc.

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)

4.

5.

6.

7.

.