beautypg.com

Step 5. the gas control system – Heat & Glo Fireplace LCOR-HV-IPI User Manual

Page 35

background image

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08

35

Step 4. Positioning, Leveling, and Securing
the Fireplace

• Place the fireplace into position.

• Level the fireplace from side to side and from front to

back.

• Shim the fireplace with non-combustible material, such

as sheet metal, as necessary.

• Secure the fireplace to the framing by nailing or screwing.

• Holes are provided in the base pan for securing the unit

to the floor.

!

The diagram below shows how to properly position, level,
and secure the fireplace.

Figure 31. Proper Positioning, Leveling, and
Securing of a Fireplace

Step 5. The Gas Control System

WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.

Figure 32. Gas Control System

IPI PILOT

!

WARNING: CONTINUOUS 110-120 VAC
SERVICE MUST BE WIRED DIRECTLY TO

THE FIREPLACE JUNCTION BOX IN A IPI SYSTEM.

Intermittent Pilot Ignition (IPI) System
This system includes a 3V control valve, electronic module
and intermittent pilot.

FLAME

SENSOR

ROD

NAILING

TABS

(BOTH SIDES)