beautypg.com

Notice, Safety opera tion maintenance setup – Harbor Freight Tools 50 FOOT DRAIN CLEANER WITH POWER FEED 68285 User Manual

Page 14

background image

Page 14

For technical questions, please call 1-800-444-3353.

Item 68284 68285

Manual Feed Operation (For Item 68285)

TO PREVENT SERIOUS INJURY FROM TWISTED OR BROKEN CABLES, CABLE ENDS WHIPPING AROUND,

MACHINE TIPPING, CHEMICAL BURNS, INFECTIONS, ELECTRIC SHOCK AND OTHER CAUSES:

Follow operating instructions for your model explicitly.

Since drains likely contain hazardous chemicals or bacteria, wear appropriate protective equipment, such as:

• ANSI-approved splash-resistant safety goggles and respirator under face shield.
• Latex, rubber or other liquid barrier gloves under heavy-duty LEATHER work gloves.

Do not use a glove you are not currently wearing or a rag to hold the rotating cable. Cloth materials

can tangle in the rotating cable, leading to serious personal injury. Before use, inspect gloves

to be sure they are free of defects or loose sections that could get caught in Drain Cleaner.

• Rubber soled, non-slip shoes to help prevent slipping and electric shock.

1. Position the Drain Cleaner two feet from the drain.

2. Position the Drain Cleaner so that you can

operate Foot Switch while having one hand on

cable at all times. This will keep cable from

hazardously “whipping” when activating the

Drain Cleaner. Also, make sure Rotation Switch

on top of Drain Cleaner is within reach.

WARNING! Only one person should feed cable

and operate Foot Switch. Do not operate

Drain Cleaner with one person controlling cable

and another person controlling Foot Switch.

This can cause cable to kink, twist, or break,

which can also lead to serious personal injury.

3. Make sure Rotation Switch is in Forward position.

4. With the Drain Cleaner off, pull the cable out

of drum and feed into the drain. Gradually

work the cable as far into the drain as it will go.

5. Step on the Foot Switch and continue

feeding cable into the drain.

6. As you feed cable, you may feel and see cable slow

down and/or start to wind or load up (a “twisting” or

“squirming” motion). This may indicate a change

in drain line (such as a drain trap, elbow, etc.),

a build up in the drain (mud or grease), or the

actual blockage. Continue to slowly feed the

cable until the cable reaches the blockage.

WARNING! Do not allow cable to build up

outside drain. This can cause cable to

twist, kink or break. When working with larger

sewers or septic tanks, minimize the amount of

cable fed to prevent kinking and knotting of cable.

7. If the cable becomes lodged in a narrow part of

the drain or in a drain trap, allow the cable to try

and work itself past the obstruction. If cable still

won’t pass obstruction, release pressure from

the Foot Switch and use sharp downward thrusts

to try and pass obstruction. Once cable is past,

press the Foot Switch and continue feeding.

NOTICE

Rotation Switch controls rotation of drum only. DO NOT USE ROTATION SWITCH

REVERSE POSITION WHILE REMOVING CABLE FROM PIPE. Use reverse direction

only momentarily for relieving pressure or untangling cable from a blockage.
Warranty void if cable damaged from allowing motor to twist excessively against blockage,

or if drum is run in reverse long enough to unwind cable.

SAFETY