Working Through a Blockage

1. If cutting tool becomes lodged in a blockage and

Drain Cleaner is still operating, cable will start

to wind up or twist. If so, release pressure from

Foot Switch and Drain Cleaner motor will stop.

WARNING! Do not let cable build up outside drain.

2. The cable and drum will turn backwards until

the tension in the cable is released.

WARNING! Do not remove gloved hand from

cable until all the tension is released.

3. Put Power Feed Lever in “reverse” position to pull

cable back and free cutting tool from blockage.

4. If motor can’t pull cable out, release pressure from

Foot Switch and allow cable to stop spinning.

Once cable has stopped spinning, grab cable

with both gloved hands and pull cable free.

5. Once tool is free of blockage and is turning again,

slowly feed rotating cutting tool back into blockage.

Do not force tool through blockage.

Allow cutting tip to break up and

work through blockage.

CAUTION: While working through the blockage, tool

and cable can get clogged with debris from blockage,

preventing further cleaning. The cable and tool will then

need to be retrieved from drain and debris removed.

Retrieving Drain Cleaner Cable

1. Once drain is clear, turn on faucet or

use a hose to flush debris out.

NOTE: If water flow slows or stops, resume

using the drain cleaner to locate and clear

blockage further down the drain.

2. To retrieve cable, set Power Feed Lever

in reverse (up) position but make sure

Rotation Switch is still in

Forward position.

WARNING! Do not retrieve cable with

Rotation Switch set in Reverse position.

3. Keep one hand on cable. The cable can

get caught while being retrieved.

4. Continue retrieving cable until you can pull cable

by hand. Release foot from Foot Switch.

WARNING! Do not pull cable from drain

while cable is still rotating. The cable can

whip around, causing serious injury.

5. Place Rotation Switch in OFF position,

dry your hands, unplug machine.

6. Release Tension Knob tension and pull remaining

cable from drain by hand and feed into Drain Cleaner.

If needed, change cutting tool and continue cleaning.

NOTICE

Rotation Switch controls rotation of drum only. DO NOT USE ROTATION SWITCH

REVERSE POSITION WHILE REMOVING CABLE FROM PIPE. Use reverse direction

only momentarily for relieving pressure or untangling cable from a blockage.
Warranty void if cable damaged from allowing motor to twist excessively against blockage,

or if drum is run in reverse long enough to unwind cable.

SAFETY