beautypg.com

Operation, Manual mode auto test – Heath Zenith Secure Home SH-9250-WH User Manual

Page 12

background image

-12-

598-1341-00

Operation

* resets to Auto Mode at dawn.

Mode:

On-Time:

Works: Day Night

Test

5 Sec

x

x

Auto

1, 5, or 20 min.

x

Manual

Until Dawn*

x

MANUAL MODE

... back on.

1 Second OFF

then...

Move ON-TIME Switch

to 1, 5, or 20 minutes

Flip light switch

off for one second

then back on*

* If you get confused while switching modes,

turn the power off for one minute, then back
on. After the calibration time, the control will
be in the AUTO mode.

MANUAL MODE

AUTO

TEST

Manual Mode only works at
night because daylight returns
the sensor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual Mode only works with
the ON-TIME switch in the 1,
5, or 20 minute position.

RANGE

Turn Range control to the desired
setting.

TEST MODE

AUTO MODE

ON TIME

TEST

1 5 20

BO

O

ST

MIN

TEST 1 5 20

RANGE

MAX

ON-TIME

BO

O

ST

MIN

TEST 1 5 20

RANGE

MAX

ON-TIME

Put the ON-TIME switch in the 1,
5, or 20 minute position.

Slide the ON-TIME switch to
TEST and turn the Range control
to the center of its adjustment.

This manual is related to the following products: