Heat & Glo Fireplace VRTIKL-AU User Manual
Page 8

8
Heat & Glo • VRTIKL-AU • 2123-900 • 7/07
f
c
n
I
openable
window
j
j
j
door
h
h
h
T
e
e
P
T
g
k
k
d
b
d
M
a
c
g
See note 2
See note 3
T
T = Flue terminal
M = Gas meter
Shading indicates prohibited
I = Mechanical air inlet P = Electricity meter or fuse box
areas for fl ue terminals
a - Below eaves, balconies or other projections:
MIN. CLEARANCE (mm)
Appliances up to 50 MJ/h input ......................................................................................... 300
Appliances over 50 MJ/h input .......................................................................................... 500
b - From the ground or above a balcony .................................................................................... 300
c - From a return wall or external corner .................................................................................... 500
d - From a gas meter (M) ......................................................................................................... 1000
e - From an electricity meter or fuse box (P) .............................................................................. 500
f - From a drain or soil pipe ....................................................................................................... 150
g - Horizontally from any building structure (unless appliance approved
for closer installation) or obstruction facing a terminal .......................................................... 500
h - From any other fl ue terminal, cowl, or combustion air intake ................................................ 500
j - Horizontally from an openable window, door, non-mechanical air
inlet, or any other opening into a building, with the exception of sub-fl oor ventilation:
Appliances up to 150 MJ/h input ....................................................................................... 500
Appliances over 150 MJ/h input ...................................................................................... 1500
k - From a mechanical air inlet, including a spa blower .......................................................... 1500
n - Vertically below an openable window, non-mechanical air
inlet or any other opening into a building, with the exception of .................................. See table
sub-fl oor ventilation ............................................................................................................ below
NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest
part of the terminal.
2. Prohibited area below electricity meter or fuse box extends to ground level.
3. See clause 5.13.6.6 for restrictions on a fl ue terminal under a roofed area.
4. See Appendix J, Figure J1(a) and J2(a) for clearances required from a fl ue terminal to a LP Gas
cylinder. A fl ue terminal is considered to be a source of ignition.
MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS
OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES
CLEARANCE ‘n’ (mm)
Space Heaters
All other appliances
Up to 50 MJ/h input
Up to 50 MJ/h input
Over 50 MJ/h & up to 150 MJ/h
Over 150 MJ/h input
150
500
1000
1500