4 in. [102 mm, D. frame the fireplace, C. sidewalls/surrounds – Hearth and Home Technologies EL36 User Manual
Page 20
![background image](/manuals/95015/20/background.png)
20
A
Fireplace
Opening
B
Outside
Dimensions
in.
36
41
mm
914
1041
in.
42
47
mm
1067
1194
Model #
EL36
EL42
B
A
9 3/4 in.
[248 mm]
12 in.
[305 mm]
12 in.
[305 mm]
11 1/4 in.
[286 mm]
FLUSH
FRONT
4 in.
[102 mm]
BRICK
FRONT
50° angle
39° angle
D. Frame the Fireplace
Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
• Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.
• Framing across the top of fireplace must be above top standoffs.
B
C
A
2 in. (51 mm)
min. air space
clearance
from chimney.
Header MUST NOT be notched!
D
D = extra space needed for outside air connection.
If outside air duct has no bend, this dimension may be
reduced as long as minimum clearances are met.
Model
A
B*
C**
D
in.
42
21 1/2
39 3/4
8
mm
1067
546
1010
203
in.
48
21 1/2
39 3/4
8
mm
1219
546
1010
203
* If interior of chase will be drywalled, add the thickness to
this measurement.
** Adjust header height for a raised floor under fireplace.
EL36
EL42
Figure 6.4 Framing the Fireplace
C. Sidewalls/Surrounds
• Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fireplace opening.
• Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area,
Figure 6.3.
Figure 6.3 Mantel Leg or Wall Projections (Acceptable on both sides of opening)
Heatilator • EL36/EL42 • 4044-132 • Rev AD • 7/12