Edge groomer
replacement
When to replace
The edge groomers, located on both
sides of the nozzle, should be replaced
when they no longer extend past the sur-
face of the bottom plate.
What to buy
When purchasing edge groomers, ask for
Hoover
part no. 39511004.
How to replace
Disconnect cleaner from electrical
outlet.
1. Remove hood and brush roll cover as
shown in Figs. 3-9 to 3-12.
H
B
E
C
A
G
B
A
2. Pull off both old edge groomers (G).
3.Push each new groomer onto the 3
tabs (H), starting with one of the end
tabs. Then push the groomer onto the
middle and remaining end tab.
4. Replace brush roll cover and hood as
shown in Figs. 3-16 and 3-17.
Powered hand tool
Agitator brush roll
replacement
When agitator brush roll brushes are
worn, the brush roll should be replaced.
Ask for HOOVER
part no. 48414088.
How to replace
Disconnect cleaner from electrical
outlet.
1. Remove tool from hose and turn it so
bottom faces up. Press the latches on
either side of tool and remove bottom
plate (A).
2. Unscrew the two Philips screws and
remove belt guard (B).
3. Remove agitator including end plates
(C) and discard.
4. Inspect belt to ensure that it is in
good condition. If belt is cracked,
gouged or broken, replace it (see follow-
ing section).
5. Insert brush roll through belt and
position belt over gear teeth (D) on
brush roll.
3-24
6. With curved ends down, slide end
plates (C) of brush roll into slots (E) on
tool.
3-25
7. Replace belt guard (B) making sure
not to pinch brush bristles in guard.
Turn agitator, making sure it rotates
freely.
Replace and tighten screws.
3-26
8. To replace bottom plate (A), insert the
four tabs on edge of bottom plate into
slots on front of tool.
Pivot bottom plate down and snap
closed.
C
D