beautypg.com

Installation procedures, Piping connection – haier AP602AKEAA User Manual

Page 26

background image

24

Installation procedures

2. Piping connection of indoor unit

Arrangement of piping and drainage pipe

After opening inlet grill, you will see a control
box as shown in the Fig.
Remove the cover before wiring work.

Cut away, with a hammer or a saw, the lid for piping according to piping
direction.

According to the piping method, connect the piping on indoor unit with union of

connecting pipe.

Arrange the piping as per the wall hole and bind drain hose connecting electric cable

and piping together with polyethylene tape.

Insert the bound piping connecting electric cable and drain hose through wall hole

to connect with outdoor unit.

Insulation material

Copper tube

Drain hose

Connecting electric cable
for indoor and outdoor unit

Piping connection

Connecting method

Apply refrigerant oil at half union and flare nut.

To bend a pipe, give the roundness as large as possible not to crash the pipe.

When connecting pipe, hold the pipe centre to centre then screw nut on by hand,refer

to Fig.

Be careful not to let sundries, such as sands enter the pipe.

1.

Forced fastening without centering may

damage the threads and cause a gas leakage.

Pipe dia

Fastening torque

Liquid pipe 9.52mm(3/8")

32.7-39.9N.m

Gas pipe 19.05mm(3/4")

97.2-118.6N.m

SLEEP

ON/OFF

MODE

FAN

SET

TEMP

HUMI

HEALTH

TIMER

TEMP+

TEMP-

HEALTH

This manual is related to the following products: