beautypg.com

Remote intelligent power supply, Power supply, Features – Honeywell INTELLIGUARD 9000 User Manual

Page 3

background image

INTELLIGUARD 9000™ SECURITY SYSTEM

3

74-3035—2

Wiring Connections: Table 1 describes the connections

between the I9000 CU and its input and output devices. Use a

RS-232 cable to connect the CU to the EBI. Use twisted pair

cable to connect the RS-485 CU ports to the I9000 input and

output devices.

NOTE: All devices should be equally divided among the two

RS-485 communication lines to maximize system

performance. See Control Center 2 Keypads and

Area Keypads sections for details.

Enclosure: 0.06 in. (1.52 mm) cold rolled steel.

Dimensions: 14-7/16 in. (367 mm) wide x 10-5/16 in. (262

mm) high x 3-1/8 in. (79 mm) deep.

Weight: 8.66 lb (3.93 kg), without batteries.

Approvals: UL, ULC, CE.

Table 1. I9000 CU Cable, Baud Rate Connections to Input,

Output Devices.

NOTE: Device to CU wire gauge is 22 AWG. Voltage drops

due to load and cable length may require an increase

in conductor size to ensure devices remain within

operational limits.

Power Supply

The I9000 and the RIPS operate from 16 Vac, 50/60 Hz (37 to

40 VA) provided by a locally supplied power transformer. For

ULI installations, this is a Silent Knight model 9220

Transformer with Silent Knight model 4165 Enclosure or listed

equivalent. For ULC installations (Canada only), this is a

5660-051 Honeywell Transformer Assembly.

Remote Intelligent Power Supply

A Remote Intelligent Power

Supply (RIPS) consists of an

I9000 enclosure containing the

8003-295 Intelligent Switching

Power Supply (ISP) without an

ICP II Control Board. The RIPS

is required when the installation

power requirements exceed the

available control unit power.

Each I9000 CU supports a maximum of seven RIPS. The

control unit supports up to eight ISPs (four per RS-485 port),

seven in the RIPS (one per RIPS) and one located in the

I9000 control unit enclosure. Depending on the installation

power backup requirements, up to two batteries can be

connected to each ISP. When the programmable outputs are

used, two batteries are recommended for those respective

RIPS.

Features

• Same as ISP features except the tamper input is factory

wired to the RIPS enclosure tamper switch.

• When cover is closed, the red LED Communication

Indicator is automatically disabled to save power.

Model: 8003-217 Remote Intelligent Power Supply (RIPS).

Transformer Electrical Ratings: Each RIPS must have its

own transformer connected to a non-switched electrical cir-

cuit.

Type: Class II Energy Limiting.

Output Voltage: 16 Vac.

Output Current: 2.3A.

Power Rating: 37 VA.

RIPS Electrical Ratings:

Operating Voltage: 13.6 Vac to 17.6 Vac.

ISP Power Consumption During AC Failure: 20 mA at

13.8 Vdc (maximum battery voltage). Add programmable

output load current to this value if the output is used.

Outputs: 2 x 400 mA maximum at 12.9 Vdc ± 4%. One pro-

grammable switched output at 1A, 12 Vdc.

NOTE: Power for the ISP programmable switched output is

partly obtained from the standby batteries. There-

fore, this output should be used to drive loads such

as sirens and bells for short durations (15 minutes

maximum). Otherwise the battery capacity will be

reduced and this will affect the total backup time

available for the devices connected to that ISP.

Standby Batteries:

Model: YUASA P/N NP7-12 or equivalent.

Electrical Ratings: 12V, 7 Ah.

Type: Sealed lead acid.

Quantity: Two maximum.

Dimensions: 2-9/6 in. (65 mm) wide x 3-7/8 in. (98 mm) high

(including terminals), x 6 in. (152 mm) deep.

Weight: 6.17 lb (2.65 kg).

Communication: RS-485 receiving and transmitting signals.

Enclosure: 0.06 in (1.52 mm) cold rolled steel.

Dimensions: 14-7/16 in. (367 mm) wide x 10-5/16 in.

(262 mm) high x 3-1/8 in. (79 mm) deep.

Weight: 8.62 lb (3.91 kg).

Approvals: UL, ULC, CE.

Designation

COM1, COM2

COM3

Application

I9000 CU and

peripherals

EBI Interface

Electrical Interface RS-485

RS-232

Cable

Twisted Pair (two or

three pairs)

Shielded Cable,

four conductors

Maximum Distance 3277 ft (999m)

75 ft (22m)

Baud Rate

4800 Baud

75-2400 Baud,

Programmable

Word Format

10 Bits (Start, 7

Data, Even Parity,

Stop)

12 Bits (1 Start, 8

Data, 1 Parity, 2

Stop)