beautypg.com

Specifications, I9000 control unit, Intelligent switching power supply (isp) – Honeywell INTELLIGUARD 9000 User Manual

Page 2: Intelligent communications processor ii (icp ii)

background image

INTELLIGUARD 9000™ SECURITY SYSTEM

74-3035—2

2

All events are sorted by day and date and then recorded in an

event log.

The I9000 recognizes a maximum of 99 users, plus one

reserved for service personnel, and five security levels with

individual identification numbers (ID) and passwords.

SPECIFICATIONS

Each component of the I9000 has the following temperature

and humidity requirements:

Temperature Ratings: 32°F to 120°F (0°C to 49°C).

Humidity Ratings: 5% to 95% at 86°F (30°C) RH, non-

condensing.

I9000 Control Unit

The Control Unit includes the

8003-295 Intelligent Switching

Power Supply (ISP) and the

8003-331 Intelligent

Communications Processor II

(ICP II). The I9000 Control Unit

supports up to 62 devices, 31

on each of two communication

ports, with 512 input points and

64 output points. The Control

Unit receives an intrusion

alarm signal from a BIC-6, BIC-2, or HEDS IV. The CU

processes the signal and sends it to the EBI, output devices,

or both. The EBI uses the signal to take the appropriate

action. The MOM, BIC-6 (configured for output), BIC-2,

BIC-2 HU, or ISP output activates any local alarms such as a

siren, light, or buzzer that are attached to the system.

The control unit supports up to eight ISPs, one of these is the

ISP contained in the I9000 Control Unit enclosure itself and

counts as one of the 62 devices. The other ISPs are located in

RIPs, one ISP per RIPS. Depending on the installation power

backup requirements, up to two batteries can be connected to

the ISP. When the ISP programmable output is used, two

batteries are recommended.

For added security, system configuration is only accessible

using the service technicians ID and Code with the control unit

in tamper alarm.

Model: 8003-332 I9000 EBI/Orbix Control Unit.

Firmware:

8950-109: Supports the I9000 EBI/Orbix protocol (included).

8950-100: Only supports existing XSM installations.

NOTE: Firmware 8950-100 (SMP protocol) must be ordered

separately and field swapped at installation time.

Electrical Ratings:

Transformer: Must be connected to a non-switched electrical

circuit.

Type: Class II Energy Limiting.

Output Voltage: 16 Vac.

Output Current: 2.3A.

Power Rating: 37 VA.

Intelligent Switching Power Supply (ISP)

ISP FEATURES
• Red LED Communication Indicator is disabled if no

jumper is present on the ISP tamper input.

• Green LED AC On Indicator.
• Switch selectable address (0, 1, 2, or 3). Learned using

CC2 or PRO9000.

• Switch selectable programmable output mode (steady

or pulsing).

• Status transmission (Low Battery, AC Fail, Tamper).
• RS-485 receiving and transmitting signals.

Electrical Ratings:

Operating Voltage: 13.6 Vac to 17.6 Vac.

ICP Power Consumption during AC failure: 20 mA at 13.8 Vdc

(maximum battery voltage). Add programmable output load

current to this value if the output is used.

Outputs: 2 x 400 mA maximum at 12.9 Vdc ± 4%. One pro-

grammable switched output at 1A, 12 Vdc.

NOTE: Power for the ISP programmable switched output is

partly obtained from the standby batteries. There-

fore, this output should be used to drive loads such

as sirens and bells for short durations (15 minutes

maximum). Otherwise the battery capacity will be

reduced and this will affect the total backup time

available for the devices connected to that ISP.

Standby Batteries:

Model: YUASA P/N NP7-12, or equivalent.

Electrical Ratings: 12V, 7 Ah.

Type: Sealed lead acid.

Quantity: Two, maximum.

Dimensions, maximum: 2-9/16 in. (65 mm) wide x 3-7/8 in.

(98 mm) high (including terminals), x 6 in. (152 mm) deep.

Weight: 6.17 lb (2.65 kg).

Intelligent Communications Processor II (ICP II)

ICP II FEATURES
• Enclosure tamper switch input.
• Two RS-485 ports for communicating with peripheral

devices (receiving and transmitting signals).

• One RS-232 port for communicating with an EBI

station, or for remote programming from a PC via

PRO9000 (receiving and transmitting signals).

• Red communication status LEDs for all three ports. To

save power, LEDs disabled when tamper normal.

• On-board independent battery backup for Real Time

Clock and data memory. Ten year battery life.

• Reports a loss of Real Time Clock operation to the EBI

(F/W 8950-109 only; must be programmed in I9000).

• Reports a loss in device communication (must be

programmed in I9000).

• Push button switch and yellow LED cold start

indicator.

Electrical Ratings:

Operating Voltage: 10 Vdc to 18 Vdc.

ICP II Power Consumption: 55.4 mA at 14.5 Vdc.