RECOMMENDED MINIMUM WIRE GAUGE FOR ExTENSION CORDS*

(120 OR 240 VOLT)

NAMEPLATE

AMPERES

(at full load)

ExTENSION CORD LENGTH

25 Feet

50 Feet

75 Feet

100 Feet 150 Feet

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – .0

18

16

14

12

12

.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

SYMBOLOGY

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute (RPM)

UNPACKING

When unpacking, check to make sure all the parts shown on the

Parts List at the

end of the manual are included. If any parts are missing or broken, please call Harbor
Freight Tools at the number shown on the cover of this manual as soon as possible.