beautypg.com

Honeywell Q674F User Manual

Page 7

background image

69-0268—11

7

T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES

H1

FALL

C

L1
(HOT)

L2

1

EM. HT.
LED (RED)

AUX. HT.
LED (GRN)

W3

O

L

G

R

W2

E

X

X2

B

W1

Y

AUX. HT. RELAY

EM. HT. RELAY

HEAT
CHANGEOVER
VALVE

W1 RELAY

COMPRESSOR
RELAY

W3 RELAY

COOL CHANGEOVER
VALVE

COMPRESSOR
MONITOR

FAN RELAY

H2

FALL

H1
ANTICIPATOR

C ANTICIPATOR

H2
ANTICIPATOR

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

REMOVE JUMPER WHEN W1 RELAY IS USED.

FACTORY-INSTALLED JUMPER.

1

M5067

FAN
SWITCH

AUTO

ON

SYSTEM
SWITCH

EM. HT.

HEAT

OFF

COOL

3

2

2

3

THERMOSTAT

SUBBASE

SYSTEM COMPONENTS

1

2

3

4

5

6

11

Fig. 8. Internal schematic and typical hookup for T874R/Q674L in heat pump system. Includes CHECK, EM. HT.

and AUX. HT. LEDs.