When Trouble Happens

1. Error display

Indoor unit malfunction display code

Please keep this manual carefully and safely.

Outdoor unit malfunction display code

When the wire remote controller display E1,Can check the outdoor unit control board LED1 or outdoor

unit malfunction display code to sure outdoor unit malfunction.

Indoor unit malfunction

Display code

Float switch or water motor abnormal

E0

Outdoor unit abnormal

E1

Liquid temperature sensor is abnormal

E3

Gas temperature sensor is abnormal

E4

Indoor unit adress abnormal

(Firstly you saw E5 in controller LCD,

and then the failure code is changed

from E5 to E9)

E5

The communication with electronic

expansion box is abnormal

E7

The communication between the

wire remote controller and indoor

unit control board is abnormal

E8

The communication between indoor
and outdoor unit is abnormal

E9

Water temp. sensor is abnormal (Only

used for the twin energy source function)

E0

Display code

Indoor unit malfunction

Remote controller Timer and Operation indicator malfunction code
When the unit running, Timer indicator flash stand for indoor unit malfunction

When the operation indicator flashing stand for outdoor unit malfunction,Operation indicator flashing

times can't determinant outdoor unit malfunction ,You must check the outdoor unit control board LED1

flashing times or outdoor unit malfunction display code to sure outdoor unit malfunction.

Others malfunction manual plese read the outdoor unit manual.

E6

Indoor unit EEPROM data is abnormal

Timer indicator

Flashing times

Indoor unit malfunction

Flashing once

The liquid tube temperature sensor is abnormal

Flashing twice

The gas tube temperature sensor is abnormal

Flashing 3 times

The environment temperature sensor is abnormal

Flashing 4 times

The communication with outdoor unit is abnormal

Flashing 5 times

The ommunication with the electronic expansion valve control board is abnormal

Flashing 10 times Indoor unit PG fan motor is abnormal

Flashing 11 times

Indoor unit water overflow or float switch is abnormal

Flashing 12 times

Indoor unit EEPROM data is abnormal

Flashing 15 times

Water temp. sensor is abnormal£¤Only used for the twin energy source function£'